Ultrasonic sensor

Ultrasonic sensors UM12

  • Operating range: 20 mm ... 240 mm
  • Resolution: ≥ 0.069 mm
  • Detection, measurement, or positioning with ultrasound technology
  • Proven M12 housing design ensures compatibility with other technologies
  • The sensor's immunity to external factors enables it to take accurate measurements even in dirty, dusty, humid, and foggy conditions
  • Variants with PNP/NPN digital output or analog output

Ultrasonic sensor

Ultrasonic sensors UM18

  • Operating range: 20 mm ... 1,000 mm
  • Resolution: 0.069 mm ... 0.2 mm
  • Rugged, reliable ultrasound technology
  • Reliable measurement, regardless of material color, transparency, gloss, or ambient light
  • Easy integration due to a short M18 housing, straight or angled
  • Measurement filters and variants with temperature compensation for reliable measurement results and very high process reliability

Ultrasonic sensor

Ultrasonic sensors UM30

  • Operating range: 30 mm ... 6,000 mm
  • Resolution: ≥ 0.18 mm
  • ObSB mode enables detection of any object between the sensor and a taught-in background
  • Reliable measurement, regardless of material color, transparency, gloss, or ambient light
  • Display enables fast and flexible sensor adjustment
  • Immune to dirt, dust, humidity, and fog

Ultrasonic sensor

Ultrasonic sensors UD18

  • Installation distance: 20 mm ... 60 mm, 40 mm ± 3 mm (default setting)/ 30 mm ... 70 mm, 50 mm ± 3 mm (default setting)
  • Resolution: 1 material layer
  • Double layer and splice detection for paper, cardboard, metal, and plastic
  • Reliable detection in dirty, dusty, and humid conditions thanks to the ultrasonic technology''s immunity to these environments

  • Measurement principle: Laser run time technology
  • Medium: Bulk solids
  • Non-contact and maintenance-free measurement of volume flow
  • Reduces maintenance costs by preventing belt slippage when using the Bulkscan® LMS511
  • conveyor speed: 30 m/s / ≤ 20 m/s
  • Aperture angle: 190°
  • Working range: 0.5 m ... 20 m/ 0.5 m ... 10 m
  • Enclosure rating: IP67

Flow sensor

Flow sensors FFU

  • Measurement principle: Ultrasonic sensor
  • Medium: Fluids
  • Process temperature: 0 °C ... +80 °C
  • Process pressure: Max. 16 bar/ Max. 10 bar
  • Nominal width measuring tube: DN 10/ DN 15/ DN 20/ DN 25/ DN 32/ DN 40/ DN 50
  • Maximum adjustable measuring range: 0 l/min ... 900 l/min
  • Enclosure rating: IP67

Flow sensor

Flow sensors FTMg

  • Measurement principle: Calorimetric (flow, temperature), piezoresistive (pressure)
  • Medium: Compressed air (air quality ISO 8573-1:2010 [3:4:4]), helium, argon, nitrogen, carbon dioxide
  • Process temperature: –20 °C ... +60 °C
  • Process pressure: 0 bar ... 16 bar
  • Nominal width measuring tube: DN 15/ DN 20/ DN 25
  • Indication: 128 x 128 pixels, adjustable rotary OLED display (90° steps) and 4 pushbuttons
  • Enclosure rating: IP65/ IP67

Overheight detectors

Overheight detectors HISIC450

  • Overheight detection for vehicles
  • Measured values: Overheight
  • Measurement principles: Double photoelectric switch
  • Measuring distance: ≤ 100 m, For outdoor measurement
  • Built-in lens heaters to prevent condensation or icing
  • Weather protection against snow, rain and dust clouds
  • Accessories (weather hood and mounting bracket) made of stainless steel
  • Enclosure rating: IP67

  • Early and reliable fire detection in tunnels
  • Measurement principles: Scattered light forward
  • Perfect addition to temperature cables thanks to earlier and faster detection
  • No need for protective measures during tunnel cleaning
  • Immune to gantry fog
  • Visibility (K value) measured according to the scattered light measurement principle
  • IP 6K9K enclosure rating thanks to a rugged stainless-steel housing

  • For the control of ventilation and for filter monitoring in road tunnels
  • Measured values: Visibility (K-value), NO, NO2, NOx, CO, temperature
  • Measurement principles: Differential optical absorption spectroscopy (DOAS), transmittance measurement, electrochemical cell, Resistance thermometer
  • Measuring distance: 10 m
  • Low maintenance requirements due to long maintenance interval (approx. 1 year)

  • The tunnel flow velocity measuring device for long-term operation
  • Measurement principle: Ultrasonic transit time difference measurement
  • Representative measurement across total tunnel width
  • Very reliable measurement, compared with punctual measurement methods
  • Accurate measurement even of very low flow velocities
  • Extremely rugged components made of titanium, stainless steel, or die cast

Visual range measuring devices

Visual range measuring devices VISIC620

  • Measurement of visual range for roads, tunnels, sea routes and in weather stations
  • Measured values: Standard visual range, K-value
  • Measurement principles: Scattered light forward
  • Spectral range: 640 nm ... 660 nm; Laser, protection class 2, power < 1 mW
  • Measuring ranges: 10 ... 500 m / 10 ... 16,000 m (Standard visual range)
  • Reliable measured values