APAQ C130TC INOR is Digital 2-wire transmitter for thermocouple; Type: Head mounted; Input: Thermocouple B, E, J, K, N, R, S and T; Output: 4-20 mA; Wireless communication: NFC®
| Type | Head mounted |
| Input | Thermocouple: B, E, J, K, N, R, S and T |
| Type of transmitter | Digital |
| Output | 4-20 mA |
| Measuring range | Type J: -210…+1200 °C / -346…+2192 °F Type K, N: -270…+1300 °C / -454…+2372 °F Type R, S: -50…+1750 °C / -58…+3182 °F Type B,E, T: See data sheet |
| Sensor error | NAMUR NE43 |
| Adjustments – Zero point | Any value within range limits |
| Adjustments – Minimum span | 20 °C / 36 °F |
| Ambient temperature | –40…+85 °C / -40…+185 °F |
| Humidity | 0…98% RH (non-condensing) |
| Vibration | IEC 60068-2-6,10 g |
| EMC | EN 61326-1 and EN 61326-2-3 |
| Isolation | Unisolated |
| Power supply | 6…32 VDC |
| Long-term stability | Max. drift ±0,05 % of span/year |
| Typical accuracy | Type E, J, K, N: ±1 K or ±0,2 % of span Type B, R, S, T: ±2 K or ±0,2 % of span |
| Adjustable filtering level | 0,4 to 26 s |
| Configuration | App: INOR Connect* |
| Wireless communication | NFCTM |