When it comes to measuring accuracy and maximum stability of measurement, INOR Process AB (Sweden) set high standard on the market for measurinng accuracy and maximum stability. With more than 75 years experience, Inor has built up a unique competence in temperature measuring. Inor is one of largest.

Temperature sensor

APAQ R130 TC

  • Sensor error: NAMUR NE43
  • Adjustments – Zero point: Any value within range limits
  • Adjustments – Minimum span: 20 °C / 36 °F
  • Ambient temperature: –40…+85 °C / -40…+185 °F
  • Humidity: 0…98% RH (non-condensing)
  • Vibration: IEC 60068-2-6,10 g

Temperature sensor

APAQ R130 RTD

  • Type: Rail mounted
  • Input: Pt100, Pt1000
  • Type of transmitter: Digital
  • Output: 4-20 mA
  • Measuring range: –200…+850 °C / -328…+1562 °F
  • Sensor error: NAMUR NE43
  • Adjustments – Minimum span: 20 °C / 36 °F

Temperature sensor

APAQ C130 TC

  • Digital 2-wire transmitter for thermocouple wireless communication.
  • Input: Thermocouple: B, E, J, K, N, R, S and T
  • Type of transmitter: Digital
  • Output: 4-20 mA
  • Sensor error: NAMUR NE43
  • Adjustments – Zero point: Any value within range limits
  • Adjustments – Minimum span: 20 °C / 36 °F

Temperature sensor

APAQ C130 RTD

  • Digital 2-wire transmitter for Pt100 and Pt1000 with wireless communication
  • Type: Head mounted
  • Input: Pt100, Pt1000
  • Type of transmitter: Digital
  • Output: 4-20 mA
  • Measuring range: –200…+850 °C / -328…+1562 °F
  • Sensor error: NAMUR NE43

INOR Connect

INOR Goes Wireless

  • INOR Connect offers the same great configuration capabilities as the ConSoft software but with an even more user-friendly interface.
  • INOR Connect is available for Android and iOS.
  • With ICON-BT you can configure and monitor the transmitter while it is still mounted in the process.
  • The great benefit of NFC® is the smooth and fast communication between the transmitter and the smartphone without any cables.

2-wire Transmitters

2-wire transmitter APAQ C130

  • Type: Head mounted
  • Input: Pt100, Pt1000
  • Type of transmitter: Digital
  • Output: 4-20 mA
  • Measuring range: –200…+850 °C / -328…+1562 °F
  • Typical accuracy: Max. ±0,15 K or ±0,15 % of span
  • Configuration: App INOR Connect*
  • Wireless communication: NFC®

2-wire Transmitters

2-wire transmitter APAQ R130

  • Type: Rail mounted
  • Input: Pt100, Pt1000
  • Type of transmitter: Digital
  • Output: 4-20 mA
  • Measuring range: –200…+850 °C / -328…+1562 °F
  • Typical accuracy: Max. ±0,15 K or ±0,15 % of span
  • Configuration: App INOR Connect*
  • Wireless communication: NFC®

2-wire Transmitters

2-wire transmitter IPAQ C330

  • Type: Head-mounted
  • Input: RTD, TC, mV, ohm
  • Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
  • Input thermocouple: Type B, C, D, E, J, K, N, R, S, T
  • Output: 4-20 mA
  • Galvanic isolation: 1500 VAC
  • Measuring channels: 1 channel
  • Sensor connection: 2-, 3-, 4-wire connection
  • Power supply: IPAQ-C330: 8 to 36 VDC/ IPAQ-C330X: 8 to 30 VDC

2-wire Transmitters

2-wire transmitter IPAQ R330

  • Type: Rail-mounted
  • Input: RTD, TC, mV, ohm
  • Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
  • Input thermocouple: Type B, C, D, E, J, K, N, R, S, T
  • Output: 4-20 mA
  • Galvanic isolation: 1500 VAC
  • Measuring channels: 1 channel
  • Sensor connection: 2-, 3-, 4-wire connection

2-wire Transmitters

2-wire transmitter IPAQ C530

  • Type: Head-mounted
  • Input: RTD, TC, mV, ohm
  • Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
  • Input thermocouple: Type B, C, D, E, J, K, N, R, S, T
  • Output: 4-20 mA, HART protocol
  • Galvanic isolation: 1500 VAC
  • Measuring channels: 1 channel
  • Sensor connection: 2-, 3-, 4-wire connection

2-wire Transmitters

2-wire transmitter IPAQ R530

  • Type: Rail-mounted
  • Input: RTD, TC, mV, ohm
  • Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
  • Input thermocouple: Type B, C, D, E, J, K, N, R, S, T
  • Output: 4-20 mA, HART protocol
  • Galvanic isolation: 1500 VAC
  • Measuring channels: 1 channel
  • Sensor connection: 2-, 3-, 4-wire connection

  • Hygienic compact sensor with flange DN25/38 ISO 2852 clamp connection
  • Measuring element: Pt100
  • Process temperature: -50…+200°C
  • Material: 1.4404 / 316L
  • Diameter: 6 mm
  • Output: 4...20 mA, temperature linear
  • Transmitter accuracy: ±0.15°C or ±0.15% of measuring span