Dust Monitor PFM Series Matsushima
Dust Monitor PFM Series Matsushima; Dust Monitor is a triboelectric principle; Measurement Range: 9 levels; Analog Output: 4mA to 20mA DC
Dust Switch PFM-DSW10 Matsushima
Dust Switch PFM-DSW10 Matsushima; Dust Switch is a triboelectric principle dust leak detector; Output signal: Open collector output 1 output (NPN); Enclosure: IP54; Material: Probe SUS304
Air Dust Monitor PFM-AD12 Matsushima
Air Dust Monitor PFM-AD12 Matsushima is a portable device that integrates a triboelectric dust monitor; Output signal: DC4~20mA; Measuring range: 0.1-1000mg/m3; Integration time: 0-30s
Air Particle Monitor PFM-AP01 Matsushima
PFM-AP01 Matsushima is Air Particle Monitor continuously measures airborne particulate concentration; Min. detectable size: 0.3µg; Analog output: DC4 to 20mA; Update time of concentration: 20s
Vehicle Classification and Measurement Free Flow Profiler
- Reliable vehicle measurement and classification in free-flowing and stop-and-go traffic.
- Non-contact axle counting in multi-lane traffic sites.
- ANPR, WIM and RFID transponders can also be integrated.
- Can be used in all climate zones from –40 °C to +60 °C thanks to the expanded temperature range.
- Data history of the last 50 vehicles detected in the user interface.
Vehicle Classification and Axle Counting System TICx02
- Flexible output of up to 30 vehicle classes, e.g. TLS 8+1, TLS 5+1, TLS 2+1 or Swiss 10.
- Optional non-contact axle counting in multi-lane traffic sites.
- ANPR, WIM and RFID transponders can also be integrated.
- TCP/IP interface for data transmission.
- Event logging and monitoring of system status.
Extractive gas analyzers MCS100FT
- CEMS solutions MCS100FT
- The FTIR measuring principle allows the simultaneous determination of more than 12 measuring components – tailor-made for the particular requirements of the customer.
- Lowest approved HF measuring range: 0 ... 3 mg/m³
- Automatic spectrum adjustment via AutoVAL for reliable measuring values
- Approved according to EN 15267
- Emission monitoring in waste incineration plants
- Effective HF limit value monitoring, e. g., in aluminum production
- Monitoring of gaseous emissions in cement plants or power stations
Fire detection sensor in tunnels VISIC50SF
- Early and reliable fire detection in tunnels
- Measurement principles: Scattered light forward
- Perfect addition to temperature cables thanks to earlier and faster detection
- No need for protective measures during tunnel cleaning
- Immune to gantry fog
- Visibility (K value) measured according to the scattered light measurement principle
- IP 6K9K enclosure rating thanks to a rugged stainless-steel housing
Ventilation and for filter monitoring in road tunnels VICOTEC320
- For the control of ventilation and for filter monitoring in road tunnels
- Measured values: Visibility (K-value), NO, NO2, NOx, CO, temperature
- Measurement principles: Differential optical absorption spectroscopy (DOAS), transmittance measurement, electrochemical cell, Resistance thermometer
- Measuring distance: 10 m
- Low maintenance requirements due to long maintenance interval (approx. 1 year)
Exhaust gas measurement INFRALYT N Saxon
Exhaust gas measurement INFRALYT N Saxon; Exhaust gas measurement for diesel and petrol engines; Measured components: CO, CO2, HC, O2, NO, NO2; Sampling line length: 7m; Communication interface: Bluetooth Class 1 (100m)/ USB 2.0 (Type B)
Exhaust gas measurement INFRALYT SMART Saxon
Exhaust gas measurement INFRALYT SMART Saxon; Small, compact and robust gas analyzer for measuring gasoline vehicles; Measured components: CO, CO2, HC, O2. NO; High-precision IR measuring bench according to OIML class 0; Communication interface: RS232/ Bluetooth® Class 1 (100m)
Exhaust gas measurement INFRALYT 80 Saxon
Exhaust gas measurement INFRALYT 80 Saxon; Measured components: CO, CO2, HC, C3H8, CH4, NO, SO2, O2, NO2; Communication interface: RS 232/ max 8, 0/4–20 mA; Accuracy: ≤ 3% of the measuring range end value; High-contrast color touch screen, intuitive operation