Exhaust gas measurement INFRALYT N Saxon; Exhaust gas measurement for diesel and petrol engines; Measured components: CO, CO2, HC, O2, NO, NO2; Sampling line length: 7m; Communication interface: Bluetooth Class 1 (100m)/ USB 2.0 (Type B)
Online support

Exhaust gas measurement INFRALYT N Saxon; Exhaust gas measurement for diesel and petrol engines; Measured components: CO, CO2, HC, O2, NO, NO2; Sampling line length: 7m; Communication interface: Bluetooth Class 1 (100m)/ USB 2.0 (Type B)

Function Measured components: CO, CO2, HC, O2, NO, NO2
Measurement principle Infrared absorption, electrochemical sensors
Measuring range 0 – 2.000 ppmv/ 0 – 10 Vol.-% (CO)
0 – 20 Vol.-% (CO2)
0 – 2.000 ppmv (HC)
0 – 2.500 ppmv  (NO)
0 – 500 ppmv   (NO2)
0 – 22 Vol.-%  (O2)
400 – 8.000 min-1 (Speed)*
0 – 170 °C ( Oil Temp)*
Accuracy ± 30 ppmv … 5% rel (CO)
± 0.03%vol  … 5% rel (CO)
±0.5% vol … 5% rel (CO2)
± 10 ppmv … 5% rel (HC)
± 30 ppmv … 5% rel (NO)
± 10 ppmv … 5% rel  (NO2)
± 0,01 %vol … 5% rel (O2)
Power supply AC 230 V ± 10 %
Communication interface Bluetooth Class 1 (100m)
USB 2.0 (Type B)
Sampling line length 7m
Dimensions (W × H × D) 205 mm x 420 mm x 270 mm

🔗 View all SAXON products at AUMI »»»

🔗 Official SAXON website »»»

At a glance:

  • EXHAUST ENGINE EXHAUST GAS TESTER
  • The Infralyt N is used for the rapid, comprehensive analysis of diesel and gasoline exhaust gases.
  • With its proprietary, high-precision NDIR measuring bench, it can measure CO, CO2, and HC within their respective measurement ranges.
  • The integration of electrochemical cells for rapid NO, NO2, and O2 measurement allows for an assessment of the actual pollutant content.
  • Thanks to internal condensate separation, no additional accessories are required for measurement.
  • All gas components are displayed along with engine speed and oil temperature. This information enables a clear evaluation of the processes and functions of diesel and gasoline engines, their exhaust aftertreatment systems, and their environmental impact.

Features:

  • Switchable display: Measured values ​​can be displayed as volume and mass concentration and referenced to a freely selectable reference oxygen value by simply switching between modes.
  • NOx measurement: Separate measurement of NO and NO2 using electrochemical cells enables highly accurate NOx calculation.
  • Easy maintenance: Thanks to the easily accessible filters on the back wall and the electrochemical cells in the base of the device (see illustration), the Infralyt N is easy to maintain despite its robustness.

 