2-wire Transmitters

2-wire transmitter APAQ C130

  • Type: Head mounted
  • Input: Pt100, Pt1000
  • Type of transmitter: Digital
  • Output: 4-20 mA
  • Measuring range: –200…+850 °C / -328…+1562 °F
  • Typical accuracy: Max. ±0,15 K or ±0,15 % of span
  • Configuration: App INOR Connect*
  • Wireless communication: NFC®

2-wire Transmitters

2-wire transmitter APAQ R130

  • Type: Rail mounted
  • Input: Pt100, Pt1000
  • Type of transmitter: Digital
  • Output: 4-20 mA
  • Measuring range: –200…+850 °C / -328…+1562 °F
  • Typical accuracy: Max. ±0,15 K or ±0,15 % of span
  • Configuration: App INOR Connect*
  • Wireless communication: NFC®

2-wire Transmitters

2-wire transmitter IPAQ C330

  • Type: Head-mounted
  • Input: RTD, TC, mV, ohm
  • Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
  • Input thermocouple: Type B, C, D, E, J, K, N, R, S, T
  • Output: 4-20 mA
  • Galvanic isolation: 1500 VAC
  • Measuring channels: 1 channel
  • Sensor connection: 2-, 3-, 4-wire connection
  • Power supply: IPAQ-C330: 8 to 36 VDC/ IPAQ-C330X: 8 to 30 VDC

2-wire Transmitters

2-wire transmitter IPAQ R330

  • Type: Rail-mounted
  • Input: RTD, TC, mV, ohm
  • Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
  • Input thermocouple: Type B, C, D, E, J, K, N, R, S, T
  • Output: 4-20 mA
  • Galvanic isolation: 1500 VAC
  • Measuring channels: 1 channel
  • Sensor connection: 2-, 3-, 4-wire connection

2-wire Transmitters

2-wire transmitter IPAQ C530

  • Type: Head-mounted
  • Input: RTD, TC, mV, ohm
  • Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
  • Input thermocouple: Type B, C, D, E, J, K, N, R, S, T
  • Output: 4-20 mA, HART protocol
  • Galvanic isolation: 1500 VAC
  • Measuring channels: 1 channel
  • Sensor connection: 2-, 3-, 4-wire connection

2-wire Transmitters

2-wire transmitter IPAQ R530

  • Type: Rail-mounted
  • Input: RTD, TC, mV, ohm
  • Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
  • Input thermocouple: Type B, C, D, E, J, K, N, R, S, T
  • Output: 4-20 mA, HART protocol
  • Galvanic isolation: 1500 VAC
  • Measuring channels: 1 channel
  • Sensor connection: 2-, 3-, 4-wire connection

2-wire Transmitters

2-wire transmitter IPAQ C202

  • Type: Head mounted
  • Input: RTD
  • Input RTD: Pt100
  • Type of transmitter: Digital
  • Output: 4-20 mA
  • Isolation: Unisolated
  • Measuring channels: 1 channel
  • Sensor connection: 3-wire connection

2-wire Transmitters

2-wire transmitter IPAQ R202

  • Type: Rail mounted
  • Input RTD: Pt100
  • Type of transmitter: Digital
  • Output: 4-20 mA
  • Isolation: Unisolated
  • Measuring channels: 1 channel
  • Sensor connection: 3-wire connection
  • Power Supply: Standard version: 6 to 32 VDC
  • Typical accuracy: Max. ±0.1K or ±0,1 % of span

2-wire Transmitters

2-wire transmitter IPAQ-21

  • Type: Rail-mounted
  • Input: RTD, Thermocouple, Universal
  • Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
  • Input Thermocouple: Type B, C, E, J, K, L, N, R, S, T, U
  • Output: 4-20 mA
  • Isolation: Isolated
  • Measuring channels: 1 channel
  • Sensor connection: 3-, 4-wire connection
  • Approvals: ATEX
  • Typical accuracy: ±0.1 % of span

2-wire Transmitters

2-wire transmitter IPAQ R520

  • Type: Rail-mounted
  • Input: RTD; Thermocouple; Universal
  • Input RTD: Pt10, Pt50, Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni1000, Cu10
  • Input Thermocouple: Type B, C, D, E, J, K, N, R, S, T
  • Output: 4-20 mA; HART®
  • Isolation: Isolated
  • Measuring channels: 2 channels
  • Sensor connection: 2-, 3-, 4-wire connection
  • Approvals: ATEX, IECEx, SIL2

2-wire Transmitters

2-wire transmitter MinIPAQ-L

  • Type: Rail-mounted
  • Input: RTD; Thermocouple
  • Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
  • Input Thermocouple: Type B, C, E, J, K, L, N, R, S, T, U
  • Output: 4-20 mA
  • Isolation: Unisolated
  • Measuring channels: 1 channel
  • Sensor connection: 3-, 4-wire connection
  • Typical accuracy: 0.15% of span

2-wire Transmitters

2-wire transmitter IPAQ-Lplus

  • Type: Rail-mounted
  • Input: RTD; Thermocouple; Universal
  • Input: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
  • Input Thermocouple: Type B, C, E, J, K, L, N, R, S, T, U
  • Output: 4-20 mA
  • Isolation: Isolated
  • Measuring channels: 1 channel
  • Sensor connection: 3-, 4-wire connection
  • Typical accuracy: 0.05% of span