MWLM-FM Matsushima is 26GHz Radar Level Transmitter; Application: For Powder, Liquid; Max. Measurable Distance: 70 m; Protection: IP67
Online support

MWLM-FM Matsushima is 26GHz Radar Level Transmitter; Application: For Powder, Liquid; Max. Measurable Distance: 70 m; Protection: IP67

Application For Powder
Model MWLM-PR26H
Product Code MWLM-PR26H3G MWLM-PR26H3F MWLM-PR26H3S MWLM-PR26H7G MWLM-PR26H7F MWLM-PR26H7S
Antenna Horn
Power Supply Standard: DC13–36V (DC16V or more required for LCD unit);
Ex-proof: DC20–32V ( power supplied by safety barrier KFD2-STC4-Ex1)
Power Consumption Standard Type: Approx. 704mW, Explosion-proof: Approx.540mW
Mounting G1 1/2 Thread JIS5K65A Flange Swivelling Flange (Equivalent to JIS10K100A) G1 1/2 Thread (Equivalent to JIS10K100A) Swivelling Flange (Equivalent to JIS10K100A)
Dead Zone 0.3 m below the antenna
Max. Measurable Distance 35.0 m from measuring reference zero point 70.0 m from measuring reference zero point
Transmitting Frequency Approx. 26 GHz
Transmitting Cycle Every 83 ms
Beam Angle Approx. 14 deg (approx. 28 deg including side beam) Approx. 8 deg (approx. 16 deg including side beam)
Resolution 1 mm
Allowable Fluctuation Rate 10 cm/s
Accuracy Within 1.2 m or less: ±30 mm; Over 1.2 m: ±20 mm or ±0.04% of measurement range (whichever is greater)
Temperature Error: Standard: ±0.03%/10K; Ex-proof: 0.06%/6K
Ambient Temp. (Housing) Standard: -40 to +80°C; With LCD: -20 to +60°C; Ex-proof: -20 to +50°C
1 hour is required to warm up the device if the temperature is lower than -20°C
Ambient Temp. (Antenna) Standard: -40 to +150°C; Ex-proof: -40 to +100°C
Allowable Pressure 1 MPa 490 kPa 500 kPa 1 MPa 250 kPa 500 kPa
Housing Material ADC
Antenna Material SUS316L
Protection IP67 (housing cover and lead outlet must be closed)
Lead Outlet 1-G1/2 (applicable cable size: Ø8–Ø12 mm)
Output Signal DC 4–20 mA ×1, load resistance max. 499Ω (24VDC), HART communication
Integral Time 0–999 s
Mass Approx. 2.3 kg Approx. 4.4 kg Approx. 6.1 kg Approx. 2.7 kg Approx. 5.3 kg Approx. 6.5 kg
Explosion-proof Construction Intrinsically safe construction Ex ia IIB T4 X (TIIS)
Division of Hazardous Section (Housing) Zone 1, Zone 2
Division of Hazardous Section (Antenna) Zone 0, Zone 1, Zone 2
Accessories (Option) LCD adjustment unit (GRAPHIC COM4); Data communication cable (MHM-01); PC adjustment software (M-DTM); Safety barrier KFD2-STC4-Ex1 is needed to use the explosion type.LCD display can’t be used since it’s a non explosion proof part.

 

Application For Liquid
Model MWLM-PR26C MWLM-PR26H
Product Code MWLM-PR26C1G MWLM-PR26H1G MWLM-PR26H2G MWLM-PR26H2F
Antenna Cone Horn
Power Supply Standard: DC13–36V (DC16V or more required for LCD unit);
Ex-proof: DC20–32V ( power supplied by safety barrier KFD2-STC4-Ex1)
Power Consumption Standard Type: Approx. 704mW, Explosion-proof: Approx.540mW
Mounting G1 1/2 Thread G1 Thread G1 1/2 Thread JIS5K50A Flange
Dead Zone 0.5 m below the antenna
Max. Measurable Distance 10.0 m from measuring reference zero point 20.0 m from measuring reference zero point
Transmitting Frequency Approx. 26 GHz
Transmitting Cycle Every 83 ms
Beam Angle Approx. 24 deg (approx. 48 deg including side beam) Approx. 18 deg (approx. 36 deg including side beam)
Resolution 1 mm
Allowable Fluctuation Rate 10 cm/s
Accuracy Within 1.2 m or less: ±30 mm; Over 1.2 m: ±20 mm or ±0.04% of measurement range (whichever is greater)
Temperature Error: Standard: ±0.03%/10K; Ex-proof: 0.06%/6K
Ambient Temp. (Housing) Standard: -40 to +80°C; With LCD: -20 to +60°C; Ex-proof: -20 to +50°C
1 hour is required to warm up the device if the temperature is lower than -20°C
Ambient Temp. (Antenna) Standard: -40 to +150°C; Ex-proof: -40 to +100°C
Allowable Pressure 500 kPa 1 Mpa 490 kPa
Housing Material ADC
Antenna Material PTFE SUS304 SUS316L
Protection IP67 (housing cover and lead outlet must be closed)
Lead Outlet 1-G1/2 (applicable cable size: Ø8–Ø12 mm)
Output Signal DC 4–20 mA ×1, load resistance max. 499Ω (24VDC), HART communication
Integral Time 0–999 s
Mass Approx. 1.9 kg Approx. 1.6 kg Approx. 1.9 kg Approx. 2.2 kg
Explosion-proof Construction Intrinsically safe construction Ex ia IIB T4 X (TIIS) Intrinsically safe construction Ex ia IIB T4 X (TIIS)
Division of Hazardous Section (Housing) Zone 1, Zone 2 Zone 1, Zone 2
Division of Hazardous Section (Antenna) Zone 1, Zone 2 Zone 0, Zone 1, Zone 2
Accessories (Option) LCD adjustment unit (GRAPHIC COM4); Data communication cable (MHM-01); PC adjustment software (M-DTM); Safety barrier KFD2-STC4-Ex1 is needed to use the explosion type.LCD display can’t be used since it’s a non explosion proof part.

🔗 View all MATSUSHIMA products at AUMI »»»

🔗 Official MATSUSHIMA website »»»

At glance

  • 26GHz Radar Level Transmitter provides reliable non-contact level measurement for liquids, slurries and bulk solids across a wide range of industrial tanks and process conditions. Its 26GHz operating frequency offers a balanced beam angle suitable for general-purpose applications, delivering stable performance in standard vessels and moderate vapor or dust environments.

Features

  • Workload Reduction: Maintenance-less non-contact operation offers long-term stability with minimal workload in harsh industrial environments.
  • Widely Applicable: Provides a balanced beam angle suitable for most standard vessels, enabling level measurement in liquids, slurries and bulk solids.
  • Cost-effective: Pulse radar technology offers dependable measurement accuracy and process stability at an economical price point.
  • Variety of Lineup: Total ten type of model lineup such as For Liquid, For Powder, Ex-proof, Swiveling Flange, Fixed Flange, etc.
  • HART Communication: HART communication compatible. Possible to communicate via other HART compatible instruments.
  • Customized Options: Variety of customized options available according to industrial environments such as process temperature, type of media, mounting limitations, etc.