Homepage » Product » SICK Sensor » Overheight detectors HISIC450

Overheight detectors HISIC450

Brand
Status In stock
Price: Please contact
(Call - Chat Zalo - Send Email)
  • Overheight detection for vehicles
  • Measured values: Overheight
  • Measurement principles: Double photoelectric switch
  • Measuring distance: ≤ 100 m, For outdoor measurement
  • Built-in lens heaters to prevent condensation or icing
  • Weather protection against snow, rain and dust clouds
  • Accessories (weather hood and mounting bracket) made of stainless steel
  • Enclosure rating: IP67
Online support

Features:

  • Measured values: Overheight
  • Measurement principles: Double photoelectric switch
  • Measuring distance: ≤ 100 m, For outdoor measurement
  • Response time (t90): HISIC450-N250, HISIC450-P250 ≤ 500 µs/ HISIC450-R250 ≤ 10 ms
  • Electrical safety: CE
  • Dimensions (W x H x D): 60 mm x 126 mm x 105 mm (for details see dimensional drawings.
  • Enclosure rating: IP67

Mechanics/ Electronics:

  • Power supply: 24 V DC, ± 20 %
  • Power supply

Voltage: HISIC450-R250: 24 … 240 V DC/ HISIC450-N250, HISIC450-P250: 10 … 60 V DC

Voltage: Connections; Protected against polarity; Reversal, only HISIC450-N250 and HISIC450-P250

Power consumption HISIC450-R250: ≤ 6 W

  • Digital outputs:

1 PNP output: 200 mA, Short-circuit-proof, only HISIC450-P250

1 NPN output: 200 mA, Short-circuit-proof, only HISIC450-N250

1 relay contact: 750 mA, 120 W, Electrically isolated, only HISIC450-R25

  • Temperature range: –25 °C … +55 °C
At a glance:
  • Overheight detection for vehicles
  • Reliable alarm signals – even in nasty weather conditions
  • Aluminum enclosure with anti-corrosion coating and high enclosure rating
  • Built-in lens heaters to prevent condensation or icing
  • Weather protection against snow, rain and dust clouds
  • Accessories (weather hood and mounting bracket) made of stainless steel
Technical data:
  • Measured values: Overheight
  • Measurement principles: Double photoelectric switch
  • Measuring distance: ≤ 100 m, For outdoor measurement
  • Response time (t90): HISIC450-N250, HISIC450-P250 ≤ 500 µs/ HISIC450-R250 ≤ 10 ms
  • Ambient temperature: –25 °C ... +55 °C
  • Electrical safety: CE
  • Enclosure rating: IP67
  • Digital outputs:

1 PNP output: 200 mA, Short-circuit-proof, only HISIC450-P250

1 NPN output: 200 mA, Short-circuit-proof, only HISIC450-N250

1 relay contact: 750 mA, 120 W, Electrically isolated, only HISIC450-R250

  • Dimensions (W x H x D): 60 mm x 126 mm x 105 mm (for details see dimensional drawings)
  • Power supply

Voltage: HISIC450-R250: 24 ... 240 V DC/ HISIC450-N250, HISIC450-P250: 10 ... 60 V DC

Voltage: Connections; Protected against polarity; Reversal, only HISIC450-N250 and HISIC450-P250

Power consumption HISIC450-R250: ≤ 6 W

Dimensions:
Connection diagram:
 