Industrial Sensors

Industrial Sensors

Level sensors UP56 PURE

  • Measurement principle: Ultrasonic sensor
  • Medium: Fluids
  • Measurement: Switch, Continuous
  • Process temperature: –25 °C ... +85 °C
  • Output signal: 1 x PNP + 4 mA ... 20 mA / 0 V ... 10 V/ 4 mA ... 20 mA/ 4 mA ... 20 mA, 2-wire
  • Non-contact measurement in immersion pipe of up to 1,500 mm
  • PTFE-coated membrane and GF D40 process connection made of PTFE

Pressure sensors PAC50

  • Device type: Pressure switch
  • Measuring ranges: –1 bar ... 0 bar; –1 bar ... +1 bar; 0 bar ... +6 bar; 0 bar ... +10 bar; –1 bar ... 10 bar (Gauge pressure)
  • Accuracy: ≤ ± 1.5 % of the span
  • Output signal: Configurable switching outputs PNP, NPN or push-pull analog output signal plus optional IO-Link
  • Bi-color display (green/red) clearly shows the status of the output signal (within or outside the target range)
  • Measuring range for gauge pressure (vacuum and overpressure)

Pressure sensor PHT

  • Device type: Pressure transmitter
  • Measuring ranges

Gauge pressure: 0 bar ... 0.25 bar up to 0 bar ... 25 bar

Absolute pressure: 0 bar ... 0,25 bar up to 0 bar ... 16 bar

Compound pressure: –1 bar ... 0 bar up to –1 bar ... +15 bar

  • Accuracy: ≤ ± 0.25 % of the span/ ≤ ± 0.5 % of the span
  • Output signal: Analog
  • Bi-color display (green/red) clearly shows the status of the output signal (within or outside the target range)

Pressure sensors PBT

  • Device type: Pressure transmitter
  • Measuring ranges

Gauge pressure: 0 bar ... 0.05 bar up to bar ... 1000 bar

Absolute pressure: 0 bar ... 0.1 bar up to 0 bar ... 25 bar

Compound pressure: –1 bar ... 0 bar up to –1 bar ... +24 bar

  • Accuracy: ≤ ± 1 % of the span/ ≤ ± 0.5 % of the span/ ≤ ± 0.25 % of the span/ ≤ ± 0.6 % of the span
  • Output signal: Analog 4 mA ... 20 mA, 0 V ... 5 V or 0 V ... 10 V

Sensors for T-slot cylinders MZT8

  • Cylinder types with adapter: Profile cylinder/ Tie rod cylinder/ Round body cylinder/ Dovetail groove cylinder/ SMC rail CDQ2/ SMC rail ECDQ2
  • Housing length: 24 mm
  • Supply voltage: 10 V DC ... 30 V DC
  • Output function: NC / NO
  • Can be used at temperatures up to 100 °C
  • Very rugged housing with enclosure rating IP 67, IP 68, or IP 69K extends the service life of the sensor

Sensors for T-slot cylinders RZT7

  • Cylinder types with adapter: Profile cylinder/ Tie rod cylinder/ Round body cylinder/ Dovetail groove cylinder/ SMC rail CDQ2/ SMC rail ECDQ2
  • Housing length: 29.5 mm / 32.5 mm
  • Supply voltage: 5 V AC/DC ... 30 V AC/DC/ 5 V AC/DC ... 230 V AC/DC/ 5 V AC/DC ... 120 V AC/DC/ 10 V AC/DC ... 48 V AC/DC
  • LED for indicating the output state (depending on type)
  • Enclosure rating: IP 67
  • Special features: Extended operating temperature

Position sensors MPS-T

  • Cylinder types with adapter: Round body cylinder/ Profile cylinders and tie-rod cylinders/ Dovetail groove cylinder/ SMC rail CDQ2/ SMC rail ECDQ2/ SMC cylinders with C-slot
  • Measuring range: 32 mm ... 256 mm
  • Housing length: 45 mm ... 269 mm
  • Supply voltage: 15 V DC ... 30 V DC
  • Analog outputs (for current or voltage), switching output, and IO-Link

Sensors for C-slot cylinders MZC1

  • Cylinder types with adapter: SMC rail CDQ2/ SMC rail ECDQ2/ Round body cylinder/ Profile cylinders and tie-rod cylinders
  • Housing length: 23.7 mm
  • Supply voltage: 10 V DC ... 30 V DC
  • LED for indicating the output state
  • Special features: Sensor element distance: 7.95 mm/ 2 x label holders attached

Sensors for C-slot cylinders RZC1

  • Cylinder types with adapter: SMC rail CDQ2/ SMC rail ECDQ2
  • Housing length: 26.3 mm
  • Supply voltage: 5 V AC/DC ... 120 V AC/DC
  • LED for indicating the output state

Displacement measurement sensors OD Mini

  • Measuring range: 10 mm ... 250 mm
  • Linearity: ± 10 µm ... ± 100 µm
  • Repeatability: 20 µm/ 200 µm/ 1 µm/ 6 µm
  • Compact, lightweight sensor for precise measurement
  • High machine throughput thanks to reliable measurement, regardless of brightness and color of surface
  • Optimum performance even at high production speeds

Displacement measurement sensors OD Value

  • Measuring range: 26 mm ... 500 mm
  • Linearity: ± 8 µm ... ± 1,200 µm
  • Repeatability: 2 µm/ 5 µm/ 10 µm/ 30 µm/ 60 µm/ 75 µm/ 100 µm
  • Reliable measurement independent of surface, minimizes machine downtime
  • Many measurement ranges and output interfaces make it ideal for cost-effective integration into any production environment
  • CMOS receiving element for measurement independent of surface

Mid range distance sensors Dx35

  • Measuring range: 50 mm ... 35,000 mm, 90 % remission, 18 % remission, 6 % remission, on reflective tape "Diamond Grade"
  • Repeatability: ≥ 0.5 mm
  • Accuracy: Typ. ± 10 mm, typ. ± 15 mm
  • Measuring range of 0.05 m to 12 m for natural objects or 0.2 m to 35 m for reflective tape
  • Infrared or red emitted light in laser class 1 or 2
  • Precise and reliable measurement regardless of object color extends run time and process quality
  • Flexible interface use: 4 mA to 20 mA, 0 V to 10 V, PNP output, NPN output, or IO-Link – making machine integration simple
Contact Contact AUMI