Homepage » Product » Sick sensor » Flow sensors FFU

Flow sensors FFU

Brand
Status In stock
Price: Please contact
(Call - Chat Zalo - Send Email)
  • Measurement principle: Ultrasonic sensor
  • Medium: Fluids
  • Process temperature: 0 °C ... +80 °C
  • Process pressure: Max. 16 bar/ Max. 10 bar
  • Nominal width measuring tube: DN 10/ DN 15/ DN 20/ DN 25/ DN 32/ DN 40/ DN 50
  • Maximum adjustable measuring range: 0 l/min ... 900 l/min
  • Enclosure rating: IP67
Online support

Features:

  • Measurement principle: Ultrasonic sensor
  • Medium: Fluids
  • Process temperature: 0 °C … +80 °C
  • Process pressure: Max. 16 bar/ Max. 10 bar
  • Nominal width measuring tube: DN 10/ DN 15/ DN 20/ DN 25/ DN 32/ DN 40/ DN 50
  • Maximum adjustable measuring range: 0 l/min … 900 l/min
  • Enclosure rating: IP67

Mechanics/ Electronics:

  • Power supply: 18 V DC … 30 V DC
  • Output signal: Analog output 4 mA … 20 mA, 0 mA … 20 mA current flow and temperature1 pulse/status output PNP/NPN-transistor output for flow rate meter, empty pipe detection, flow monitoring, dosing output, flow direction (dependent on type)/ Analog output 4 mA … 20 mA, 0 mA … 20 mA current flow and temperature2 pulse/status output PNP/NPN-transistor output for flow rate meter, empty pipe detection, flow monitoring1 switching input for dosing and counter reset/ Analog output 4 mA … 20 mA, 0 mA … 20 mA current flow and temperature1 pulse/status output PNP/NPN-transistor output for flow rate meter, empty pipe detection, flow monitoring, dosing output, flow direction (dependent on type)1 switching input for dosing and counter reset
  • Electrical connection: Round connector M12 x 1, 5-pin / M12 round connector x 1, 8-pin
  • Housing material: PPSU
  • Temperature range: 0 … +60°C

At a glance:
  • Flow sensor for conductive and non-conductive liquids
  • Compact design with no moving parts
  • Process temperature up to 80 °C, process pressure up to 16 bar
  • High chemical resistance due to seal-free sensor design
  • Large display with membrane keyboard
  • Integrated empty tube detection
  • Straight measuring tube reduces pressure loss, thus reducing energy costs
Technical data:
  • Measurement principle: Ultrasonic sensor
  • Medium: Fluids
  • Output signal: Analog output 4 mA ... 20 mA, 0 mA ... 20 mA current flow and temperature1 pulse/status output PNP/NPN-transistor output for flow rate meter, empty pipe detection, flow monitoring, dosing output, flow direction (dependent on type)/ Analog output 4 mA ... 20 mA, 0 mA ... 20 mA current flow and temperature2 pulse/status output PNP/NPN-transistor output for flow rate meter, empty pipe detection, flow monitoring1 switching input for dosing and counter reset/ Analog output 4 mA ... 20 mA, 0 mA ... 20 mA current flow and temperature1 pulse/status output PNP/NPN-transistor output for flow rate meter, empty pipe detection, flow monitoring, dosing output, flow direction (dependent on type)1 switching input for dosing and counter reset
  • Nominal width measuring tube: DN 10/ DN 15/ DN 20/ DN 25/ DN 32/ DN 40/ DN 50
  • Maximum adjustable measuring range: 0 l/min ... 900 l/min
Dimensions:
Connection diagram:

No documents available

guest

Oldest
Newest
Inline Feedbacks
View all comments
Contact Contact AUMI
Zalo Mess Phone Location