Homepage » Product » Fiber-optic sensors GLL170T-B333 SICK

Fiber-optic sensors GLL170T-B333 SICK

Brand SICK Sensor
Status In stock
Price: Please contact
(Call - Chat Zalo - Send Email)

Fiber-optic sensors; Digital output NPN switching mode Light/dark switching; Connection Connector M8, 3-pin; Type of light visible red light; Response time ≤ 250 µs, ≤ 50 µs

Online support

The GLL170-P333 SICK is fiber-optic sensors, sensing range max depending on the optical fiber cable used, digital output NPN-PNP switching mode Light/dark switching, Connection connector M8, 3-pin, type of light visible red light, response time ≤ 250 µs, ≤ 50 µs. Compact fiber-optic sensing head design, suitable for applications with limited installation space and enabling easy operation.

Functional principle Fiber-optic amplifier
Device type detail Stand-alone
Sensing range max Depending on the optical fiber cable used
Type of light Visible red light
Adjustment Display + operating buttons For configuring the sensor parameters
Display LED green Operating indicator Static on: power on LED yellow Status of digital output Permanently on: Switching output active Permanently off: Digital output not active Display Display of sensor functions
Supply voltage 10 V DC … 30 V DC
Digital output PNP-NPN
Switching mode Light/dark switching
Output current Imax ≤ 100 mA
Response time ≤ 250 µs, ≤ 50 µs
Switching frequency 2 kHz, 10 kHz
Time functions Switch-on delay, off delay, one shot, Without time delay
Delay time Programmable, 0 ms … 9,999 ms
Dimensions (W x H x D) 10 mm x 31.7 mm x 72.5 mm
Connection Connector M8, 3-pin
Housing Rectangular
Enclosure rating IP66 (EN 60529)
Ambient operating temperature -25 °C … +55 °C
Vibration resistance 10 Hz … 55 Hz (Amplitude 1 mm, 3 x 30 min (EN60068-2-6))
Special applications

🔗 View all genuine SICK products available at AUMI »»» 

🔗 Discover other SICK Fiber optic sensor series »»» 

🔗 View detailed specifications on the official SICK website »»» 

GLL170T-B333 SICK Fiber Optic Sensor PNP NPN – Industrial Fiber-Optic Amplifier

Overview:

  •       Stand-alone fiber-optic amplifier with selectable PNP/NPN output – compatible with virtually any PLC or control system
  •       Supply voltage range 10–30V DC, current consumption ≤ 40 mA – suitable for both 12V and 24V systems
  •       Ultra-fast response time ≤ 50 µs and switching frequency up to 10 kHz – ideal for high-speed detection applications
  •       IP66 ingress protection rating – fully dust-tight and resistant to high-pressure water jets for demanding industrial environments
  •       632 nm red LED light source with a rated service life of 100,000 hours; Free group risk classification per EN 62471
  •       Integrated timer functions: switch-on delay, switch-off delay, one-shot (monostable) – programmable from 0 to 9.999 ms
  •       On-device parameter display with integrated push-buttons for straightforward field configuration

The GLL170T-B333 is a stand-alone fiber-optic amplifier from SICK, operating on a sensing principle that depends on the type of fiber-optic cable attached. The unit supports user-selectable PNP or NPN digital output (configurable via on-device menu), a switching frequency of up to 10 kHz, a response time of ≤ 50 µs, and an IP66 ingress protection rating – making it well-suited for precise object detection in electronics manufacturing, food & beverage processing, textile production, and a wide range of industrial automation applications.

Product Overview – GLL170T-B333 SICK Fiber Optic Sensor

The GLL170T-B333 belongs to SICK’s GLL170 series – one of the most widely deployed fiber-optic amplifier families in industrial automation. As a stand-alone unit, the device integrates all signal processing electronics, a parameter display, and configuration push-buttons into a compact housing measuring just 10 × 31.7 × 72.5 mm.

A key differentiator of the GLL170T-B333 is its ability to switch between PNP and NPN output modes directly via the on-device menu, combined with selectable Light/Dark switching modes. This ensures seamless interfacing with virtually all PLC platforms currently in use, without requiring separate hardware variants for different controller types. Additionally, the unit features a dedicated Teach-in input (pin 2, white/WH conductor) for rapid threshold calibration in the field without the need for specialized tools or software.

With a switching frequency of 10 kHz and a response time of ≤ 50 µs, the GLL170T-B333 is engineered for high-throughput applications such as presence inspection on high-speed conveyors, electronic component counting, or thin-material detection in printing and packaging lines.

5 Key Specifications:

  •       Digital output: PNP or NPN (menu-selectable) – 1 discrete output
  •       Supply voltage: 10–30V DC; current consumption ≤ 40 mA (no load)
  •       Switching frequency: 2 kHz (standard) / 10 kHz (fast mode); response time ≤ 50 µs
  •       Ingress protection: IP66 – fully dust-tight and high-pressure water jet resistant
  •       Light source: 632 nm red LED; rated service life 100,000 hours

Technical Specifications – GLL170T-B333 SICK Fiber Optic Sensor

Parameter Value
Device type Fiber-optic amplifier – Stand-alone
Operating principle Dependent on fiber-optic cable type used
Light source Red LED, wavelength 632 nm
LED service life 100,000 h at ambient temperature +25°C
Supply voltage (UB) 10–30V DC (ripple ≤ 10%)
Current consumption ≤ 40 mA (no load)
Digital output 1 output (PNP or NPN, menu-selectable)
Switching mode Light/Dark switching
PNP output signal level HIGH/LOW Approx. UB – 1.5 V / 0 V
NPN output signal level HIGH/LOW Approx. UB / < 1.5 V
Max. output current ≤ 100 mA
Output circuit protection Reverse polarity protected, overcurrent protected, short-circuit protected
Response time ≤ 250 µs (standard) / ≤ 50 µs (fast mode)
Switching frequency 2 kHz / 10 kHz
Timer functions Switch-on delay, switch-off delay, one-shot (monostable), no delay
Programmable delay time 0–9.999 ms
Electrical connection M8 connector, 3-pin
Dimensions (W × H × D) 10 × 31.7 × 72.5 mm
Housing material Plastic, PC/POM
Weight 22 g
Ingress protection rating IP66 (EN 60529)
Ambient operating temperature –25°C to +55°C
Storage temperature –40°C to +70°C
Relative humidity 35–95% RH (non-condensing)
Ambient light immunity Artificial light: ≤ 5,000 lx; Sunlight: ≤ 60,000 lx
Shock resistance 50 g, 11 ms (EN 60068-2-27)
Vibration resistance 10–55 Hz, amplitude 1 mm (EN 60068-2-6)
Electromagnetic compatibility (EMC) EN 60947-5-2
Mean time to dangerous failure (MTTFd) 300 years
Mission time (TM) 20 years
Certifications CE, UKCA, cRUus, CCC exempt, RoHS
Part No. 6063342

Specifications sourced from GLL170T-B333 Datasheet – SICK AG, 2026. Download: https://www.sick.com/media/pdf/5/45/145/dataSheet_GLL170T-B333_6063342_en.pdf

Ordering Information – GLL170T-B333 SICK Fiber Optic Sensor

Model Description Part No.
GLL170T-B333 Fiber-optic amplifier, PNP/NPN output, 10–30V DC, IP66, M8 3-pin connector 6063342

For additional device variants and compatible accessories, visit: www.sick.com/GLL170

Industrial Applications – GLL170T-B333 SICK Fiber Optic Sensor

Thanks to its compact form factor, high-speed response, and compatibility with a broad range of fiber-optic cable types, the GLL170T-B333 SICK fiber optic sensor PNP NPN is well-suited for numerous industrial automation applications:

Electronics & Semiconductor Manufacturing:

Detection of miniature SMD components on high-speed conveyors, presence verification of IC chips, and detection of thin adhesive labels. The 10 kHz switching frequency supports inspection at maximum line speeds without missed detections.

Packaging & Printing:

Label detection on unwind rolls, inter-product gap checking, and packaging defect identification. The flexible Light/Dark switching mode accommodates both transmissive and reflective detection setups.

Food & Beverage Processing:

The IP66 rating permits high-pressure washdown cleaning. Suitable for cap presence detection, fill-level verification, and label inspection on high-speed bottling and canning lines.

Textile & Thin-Material Detection:

Fine-tip fiber-optic cables enable detection of threads, fabric, and thin films in confined spaces inaccessible to conventional photoelectric sensors.

Automotive & Precision Machining:

Detection of small metallic parts, bore verification, and assembly confirmation. High ambient light immunity (≤ 60,000 lx sunlight) ensures reliable operation in facilities with large skylights or open production floors.

GLL170T-B333 vs GLL170-P333

The GLL170 series is available in multiple variants. The table below positions the GLL170T-B333 with GLL170-P333: 

Criterion GLL170T-B333 GLL170-P333
Output type PNP / NPN (menu-selectable) PNP
Switching frequency 2 kHz / 10 kHz 2 kHz 
Ingress protection IP66 IP66 
Electrical connection M8 3-pin connector M8 3-pin connector
Supply voltage 10–30V DC 10–30V DC
Best suited for High-speed applications, universal PNP/NPN compatibility Detection of small objects or installations in confined spaces
Response Time ≤ 250 µs (standard) / ≤ 50 µs (fast mode) ≤ 250 µs
Weight 22g 19g
MTTFd 300 years 760 years

Frequently Asked Questions – GLL170T-B333 SICK Fiber Optic Sensor

Q1: What is the price of the GLL170T-B333 fiber optic sensor?

A: Pricing for the GLL170T-B333 depends on order quantity and delivery requirements. Contact AUMI via hotline 0917 991 589 to receive a competitive quotation along with expert guidance on selecting compatible fiber-optic cables for your specific application.

Q2: Does the GLL170T-B333 support PNP or NPN output?

A: The GLL170T-B333 supports both – PNP and NPN – selectable by the user through the on-device configuration menu. This eliminates the need to stock separate hardware variants for different PLC types, significantly reducing spare parts inventory.

Q3: Does the GLL170T-B333 require a separate fiber-optic cable?

A: Yes. The GLL170T-B333 is a fiber-optic amplifier and must be paired with a compatible fiber-optic cable to form a complete sensing system. SICK offers a comprehensive range of compatible cables within the GLL170 product family. Contact AUMI for guidance on selecting the appropriate cable type for your application.

Q4: What does the IP66 rating mean for the GLL170T-B333?

A: IP66 indicates the device is fully dust-tight (first digit: 6) and protected against powerful water jets from any direction (second digit: 6). This allows the unit to be cleaned with high-pressure water, making it suitable for food & beverage, pharmaceutical, and other demanding industrial environments.

Q5: How is the detection threshold configured on the GLL170T-B333?

A: The device features a dedicated Teach-in input on pin 2 (white/WH conductor). The operator positions the target object within the sensing field and activates the Teach-in function – the amplifier then automatically learns and stores the optimal switching threshold without requiring any external tools or software.

Q6: Where can I purchase genuine GLL170T-B333 SICK fiber optic sensors?

A: AUMI is an authorized SICK distributor in Vietnam. We guarantee 100% genuine SICK products with complete documentation including certificates of origin and conformity (CO/CQ), full manufacturer warranty, and 24/7 technical support with field service coverage across Hanoi, Ho Chi Minh City, and Da Nang.

Purchase the GLL170T-B333 SICK Fiber Optic Sensor – Contact AUMI

AUMI – Authorized SICK Distributor in Vietnam. Genuine products, full CO/CQ documentation, 24/7 technical support.

📞 Hotline: 0917 991 589 (Hanoi) | 0932 226 100 (Ho Chi Minh City)

📧 Email: [email protected]

🌐 Website: https://aumi.com.vn/

Office Locations:

  •       Hanoi: B44, Garden Villa Zone, Viet Hung Urban Area, Long Bien District
  •       Ho Chi Minh City: 2nd Floor, HS Building, 260/11 Nguyen Thai Binh, Tan Binh District
  •       Da Nang: 9th Floor, PV Bank Building, 2 Street 30-4, Hoa Cuong Ward

🔗 Official Datasheet

🔗 View all SICK products at AUMI

🔗 Explore other Industrial Sensors

guest

Oldest
Newest
Contact Contact AUMI
Zalo Mess Phone Location