The product CDF600-0100 is designed in accordance with European industrial standards, providing all essential technical specifications to help engineers easily select and integrate it into their systems. These specifications include measuring range/detection capability, accuracy, response time, output signal, power supply, IP protection rating, and operating environmental conditions.
Depending on the specific model and application, the device may support various connection options, communication protocols, or advanced features to meet the requirements of automation, safety, and reliability in industrial environments.
Below is the detailed technical specification table of the product:
| Features | |
| Brief description | Fieldbus proxy/gateway for connecting a sensor to PROFIBUS networks |
| Supported products | CLV61x – CLV65x, RFH620 |
| Cloning module support (CMC) | Integrated |
| Supports display module (CMD) | No |
| Supports power supply module (CMP) | No |
| Supports fieldbus gateway (CMF) | No |
| Interfaces | |
| Serial | ✔ , RS-232 |
| Remark | Depending on sensor connected |
| Remark | Depending on sensor connected |
| PROFIBUS DP | ✔ |
| Function | Slave |
| Data transmission rate | 9.6 kbit/s … 12 Mbit/s, automatic detection |
| Switching inputs | 2 |
| Switching outputs | 2 |
| Optical indicators | 6 LED |
| Configuration software | SOPAS ET |
| Mechanics/electronics | |
| Electrical connection | 1 x 15-pin D Sub HD female connector (DEVICE) 3 x 5-pin M12 female connector (IN 1, IN 2, OUT 1/2) 1 x 5-pin M12 female connector (PROFIBUS OUT) 1 x 5-pin M12 male connector (PROFIBUS IN) 1 x 5-pin M12 male connector (POWER) 1 x 4-pin M8 female connector (AUX) |
| Operating voltage | 18 V DC … 30 V DC |
| Power consumption | 7 W, if no sensor is connected and digital switching inputs and outputs are not connected |
| Housing | Aluminum die cast |
| Housing color | Light blue (RAL 5012) |
| Enclosure rating | IP65 (DIN 40 050) |
| Protection class | III |
| Weight | 590 g |
| Dimensions (L x W x H) | 225 mm x 76.5 mm x 47 mm |
| Scanner connection | RS-232 |
| Ambient data | |
| Electromagnetic compatibility (EMC) | EN 61000-6-4 (2007-01) / EN 61000-6-2:2005 |
| Vibration resistance | EN 60068-2-6 (1995) |
| Shock resistance | EN 60068-2-27 (1993) |
| Ambient operating temperature | –35 °C … +50 °C |
| Storage temperature | –35 °C … +70 °C |
| Permissible relative humidity | ± 90 %, Non-condensing |
| Classifications | |
| ECLASS 5.0 | 27242208 |
| ECLASS 5.1.4 | 27242608 |
| ECLASS 6.0 | 27242608 |
| ECLASS 6.2 | 27242608 |
| ECLASS 7.0 | 27242608 |
| ECLASS 8.0 | 27242608 |
| ECLASS 8.1 | 27242608 |
| ECLASS 9.0 | 27242608 |
| ECLASS 10.0 | 27242608 |
| ECLASS 11.0 | 27242608 |
| ECLASS 12.0 | 27242608 |
| ETIM 5.0 | EC001604 |
| ETIM 6.0 | EC001604 |
| ETIM 7.0 | EC001604 |
| ETIM 8.0 | EC001604 |
| UNSPSC 16.0901 | 32151705 |