Safety Laser Scanner 2D NANS3-CAAZ30AA1 SICK – EFI-pro, SIL 2, PL d
Overview
- The nanoScan3 is SICK’s most compact 2D safety laser scanner, specially designed for hazardous area protection and positioning on mobile platforms such as AGVs and AMRs.
- The device features advanced safeHDDM® scanning technology, delivering high measurement accuracy and exceptional immunity to strong ambient light, dust, dirt, and harsh industrial environments. With a height of only 80 mm, the nanoScan3 integrates easily into space-saving designs.
- The NANS3-CAAZ30AA1 belongs to the nanoScan3 Pro I/O – EFI-pro series. It offers a protective field range of up to 3 m, a warning field of 10 m, a maximum measuring range of 40 m, a scan angle of 275°, and an angular resolution of 0.17°. The scanner supports flexible configuration of up to 128 monitoring fields and 128 monitoring cases, with simultaneous monitoring of up to 8 fields. Configuration and diagnostics are performed easily via the Safety Designer software over USB or Ethernet.
Product Overview
The NANS3-CAAZ30AA1 is a 2D safety laser scanner from the nanoScan3 Pro I/O – EFI-pro series by SICK. It is optimized for hazardous area monitoring and safe navigation in mobile automation systems such as AGVs, AMRs, collaborative robots (cobots), and automated warehouses.
Thanks to the EFI-pro protocol, the AA1 version enables safe networking of multiple SICK safety devices within the same system. This significantly reduces wiring complexity and enhances system scalability. Precise measurement data is output via the Ethernet interface.
With safety certifications including Type 3 (IEC 61496), SIL 2 (IEC 61508), and PL d / Category 3 (EN ISO 13849), the NANS3-CAAZ30AA1 is suitable for applications requiring medium to high safety levels in industrial environments.
5 Key Specifications
- Protective field: 3 m | Warning field: 10 m | Maximum measuring range: 40 m
- Scan angle: 275° | Angular resolution: 0.17° | Configurable resolution: 20 / 30 / 40 / 50 / 60 / 70 / 150 / 200 mm
- Safety ratings: Type 3, SIL 2, PL d, Category 3
- Interfaces: Local I/O + EFI-pro | Configuration via Safety Designer (USB/Ethernet)
- Response time: 85 ms | Protection rating: IP65 | Operating temperature: −10 °C … +50 °C
Technical Specifications Table – NANS3-CAAZ30AA1
| Parameter |
Value |
| Protective field |
3 m |
| Warning field |
10 m |
| Maximum measuring range |
40 m |
| Scan angle |
275° |
| Angular resolution |
0.17° |
| Configurable resolution |
20 / 30 / 40 / 50 / 60 / 70 / 150 / 200 mm |
| Number of monitoring fields |
128 |
| Number of monitoring cases |
128 |
| Simultaneously monitored fields |
≤ 8 |
| Response time |
85 ms |
| Safety ratings |
Type 3 (IEC 61496), SIL 2 (IEC 61508), PL d / Category 3 (EN ISO 13849) |
| Safety outputs |
2 pairs OSSD (PNP) |
| Universal I/O |
4 |
| Interfaces |
Local I/O + EFI-pro |
| Supply voltage |
24 V DC (16.8 … 30 V DC) |
| Power consumption |
5.5 W (without output load) |
| Protection rating |
IP65 |
| Operating temperature |
−10 °C … +50 °C |
| Dimensions (W × H × D) |
106.6 × 80 × 117.5 mm |
| Weight |
0.67 kg |
Technical data according to the official SICK datasheet. Datasheet link: https://www.sick.com/media/pdf/9/89/489/dataSheet_NANS3-CAAZ30AA1_1126792_en.pdf
Important Note: The NANS3-CAAZ30AA1 is supplied as sensor without system plug. The system plug must be ordered separately. For the Pro I/O – EFI-pro version, it is recommended to select a system plug with Ethernet interface to fully support the EFI-pro protocol and measured data output. The system plug contains the integrated configuration memory, enabling quick device replacement without rewiring or reconfiguring the safety application.
Applications of NANS3-CAAZ30AA1 in Industry
Thanks to its ultra-compact design, safeHDDM® technology with excellent resistance to light, dust and dirt, and dynamic field switching capability, the NANS3-CAAZ30AA1 is an ideal solution for various indoor automation applications:
- Automated Guided Vehicles (AGV) and Autonomous Mobile Robots (AMR): Real-time monitoring of the travel path, automatic switching of protective fields according to speed and direction, while providing accurate positioning support.
- Collaborative Robots (Cobots): Safeguarding the workspace around cobots to ensure safety when humans and robots share the same area.
- Automated Warehousing & Logistics: Protection of corridors and entry/exit zones with flexible configuration of multiple monitoring scenarios.
- Production Lines & Packaging Machines: Safeguarding hazardous machinery and high-speed conveyors in industrial environments.
- Service Robots: Easy installation on compact robots used in hospitals, supermarkets, or e-commerce warehouses.
The NANS3-CAAZ30AA1 not only meets stringent safety requirements but also boosts productivity by minimizing unnecessary machine downtime and enabling more flexible automation.
Comparison: NANS3-CAAZ30AA1 (EFI-pro) vs NANS3-CAAZ30AN1 (PNP)
| Criteria |
NANS3-CAAZ30AA1 (EFI-pro) |
NANS3-CAAZ30AN1 (PNP) |
| Interfaces |
Local I/O + EFI-pro |
Local I/O (PNP) |
| Network connectivity |
EFI-pro (SICK safe device network) |
No fieldbus support |
| Suitable for |
Systems with multiple SICK devices |
Standard PLC / safety relay, single-unit systems |
| Integration |
Simplified wiring in distributed systems |
Direct wiring to safety relay / PLC |
| Integration cost |
More cost-effective when using multiple scanners |
Optimized for 1–2 scanners |
| Part number |
1126792 |
1100334 |
Note: If your system uses two or more scanners or already includes other SICK devices with EFI-pro support, the NANS3-CAAZ30AA1 is the recommended choice for optimized wiring and installation costs.
Frequently Asked Questions about NANS3-CAAZ30AA1 (FAQ)
Q1. What applications is the NANS3-CAAZ30AA1 suitable for?
A: The device is ideal for AGVs/AMRs, mobile robots, cobots, automated warehouses, and production lines that require precise and reliable hazardous area monitoring.
Q2. What safety standards does the device meet?
A: Type 3 (IEC 61496), SIL 2 (IEC 61508), PL d / Category 3 (EN ISO 13849).
Q3. What are the scanning range and protective field dimensions?
A: Protective field 3 m, warning field 10 m, maximum measuring range 40 m, scan angle 275°, response time 85 ms.
Q4. What interfaces does the NANS3-CAAZ30AA1 support and how easy is it to integrate?
A: It supports 2 pairs of OSSD outputs, 4 universal I/Os, and the EFI-pro protocol. EFI-pro enables easy networking of multiple SICK safety devices, reduces wiring, and allows measured data output via Ethernet.
Q5. What should be considered when installing the NANS3-CAAZ30AA1?
A: Pay attention to the environmental conditions (operating temperature, ambient light, dust), ensure compatibility with the existing control system, and configure the device correctly using the Safety Designer software to achieve optimum performance and safety. In addition, a suitable system plug must be ordered separately (Ethernet-enabled system plug is required for the EFI-pro version).
Contact for Purchasing the 2D Safety Laser Scanner NANS3-CAAZ30AA1
AUMI – Official authorized distributor of SICK in Vietnam. Full manufacturer warranty, complete CO/CQ documentation, and 24/7 technical support.
📞 Hotline: 0917 991 589 (Hanoi) | 0932 226 100 (Ho Chi Minh City)
📧 Email: [email protected]
🌐 Website: https://aumi.com.vn/
Addresses:
- Hanoi: B44, Villa Area, Viet Hung Urban Area, Long Bien District
- Ho Chi Minh City: 2nd Floor, HS Building, 260/11 Nguyen Thai Binh, Tan Binh District
- Da Nang: 9th Floor, PV Bank Building, No. 2 30-4 Street, Hoa Cuong Ward