Scattered light dust Measuring Devices

Scattered light dust measuring devices DUSTHUNTER SP30

  • The DUSTHUNTER SP30 is a measuring device which reliably detects very low to high dust content
  • Emission monitoring which does not require permission in industrial systems
  • Dust concentration measurements in exhaust gas ducts
  • Monitoring of cloth filters for defective filter bags
  • Ideal for monitoring electrostatic precipitators
  • Dust monitoring in grinding and dosing systems
  • Monitoring and regulation of fresh air and exhaust air systems

Scattered light dust Measuring Devices

Scattered light dust measuring devices DUSTHUNTER SP100

  • The DUSTHUNTER SP100 is a type-approved measuring device with probe for very low to medium dust concentrations
  • For very low to medium dust concentrations
  • For small to medium duct diameters
  • Emissions monitoring at power plants and waste incineration plants
  • Monitoring of filter systems
  • Measurements in exhaust gas or exhaust ventilation ducts

Scattered light dust Measuring Devices

Scattered light dust measuring devices FWE200DH

  • The FWE200DH dust measuring device is designed to continuously measure dust concentrations in wet flue gas
  • For very low to medium dust concentrations
  • Gas sampling and return combined in one probe
  • Contamination check
  • Monitoring of wet gas scrubbing facilities
  • Measurement in saturated gas downstream of desulfurization plants
  • Determination of dust concentrations in wet exhaust air and in technological processes

  • Gas flow measuring instruments FLOWSIC100
  • Integrated measurement via duct diameter for types H, M, and S
  • Probe version PR for cost-saving, single-sided installation in duct
  • No purge air required for applications with gas temperatures up to 260 °C
  • Continuous emission measurement during power generation
  • Emission monitoring in waste incineration plants
  • Emission measurement in the processing industry (cement, iron and steel, glass)
  • Emission monitoring in the chemical and hydrocarbon processing (HPI) industry
  • Emission monitoring in the paper and textiles industry
  • Flow measurements and process control in e. g., heating and ventilation systems

  • The FLOWSIC100 Flare product family is designed for flare gas and steam flow measurements
  • Innovative design for very high gas velocities and gas temperatures up to 280 °C
  • Control cycle for automatic self-diagnosis / signal optimization
  • Emissions control for accounting of CO2 emissions
  • Detection of flare gas leaks
  • Measurement of steam flow
  • Monitoring of steam injection when burning flare gas
  • Monitoring of gas losses
  • Exact mass balance and process optimization

  • A Pitot tube flow velocity measuring device
  • The SMC222 series Pitot tube flow velocity measuring device is suitable for measuring the flow of steam, air, and other such mediums
  • Provides users with a standard 4 ... 20 mA output proportional to the flow rate
  • Online measurement of industrial boiler fuel gas emissions
  • Managing flow rate of mediums such as steam or air, especially useful for measuring flow rate in large-diameter ducts

In-situ gas analyzers

In-situ gas analyzers GM32

  • In-situ gas analyzers GM32
  • The GM32 in-situ gas analyzer measures SO2, NO, NO2 and NH3
  • No gas sampling, no gas transport, no gas conditioning
  • Up to eight measuring components at the same time, plus process temperature and pressure
  • DOAS and CDE evaluation process
  • Numerous independent measuring ranges with consistent accuracy
  • Automatic self-test function (QAL3) without test gases
  • Overpressure encapsulated design for ATEX Zones 1 and 2
  • For monitoring and control in flue gas purification,such as denitrification plants, desulfurization plants and converters
  • Emissions monitoring according to EU directives or local regulations
  • TRS emissions monitoring in the Kraft pulp industry.

In-situ gas analyzers

In-situ gas analyzers GM35

  • In-situ gas analyzers GM35
  • Simultaneous or as individual measurement: the GM35 gas analyzer measures CO2, H2O and CO, or N2O, as well temperature and pressure
  • No gas sampling and conditioning
  • Gas testable version of measuring probe available
  • Emission monitoring according to EN 14181, e. g., in power or cement plants
  • Monitoring of the combustion efficiency in hazardous waste incineration
  • Process monitoring in urea production

In-situ gas analyzers

In-situ gas analyzers Zirkor200

  • In-situ gas analyzers Zirkor200
  • ’s ZIRKOR200 gas analyzer provides very robust, reliable, and suitability-tested oxygen measurement for small and large combustion plants
  • Electrochemical cell with extremely long service life due to innovative protection mechanisms
  • Fully automated adjustment mechanism integrated into the control unit
  • ZIRKOR remote app for remote access to the analyzer
  • Suitability-tested according to EN 15267
  • Ex version for ATEX/IECEx, Zone 1 and Zone 21
  • Oxygen monitoring for process control
  • Monitoring of inert gas atmospheres

In-situ gas analyzers

In-situ gas analyzers GM700

  • In-situ gas analyzers GM700
  • The GM700 is able to measure several gas components, such as NH3, HF, HCl or H2O
  • High selectivity due to high spectral resolution
  • Overpressure encapsulated design for ATEX Zone 2
  • Ammonia slip measurement in DeNOx plants
  • Emission monitoring of hydrogen fluoride in aluminum smelters
  • Ammonia measurement in exhaust gas of combustion engines
  • Ammonia measurement in composting or waste incineration plants
  • HCI measurement in combustion plants

Cold-dry Extractive gas analyzers

Extractive gas analyzers GMS800

  • Extractive gas analyzers GMS800
  • Measured values: Ar, CH4, CH3OH, C2H2, C2H2F4, C2H4, C3H6, C3H8, C4H6, Cl2, CO, CO2, COCl2, COS, CS2, H2, H2S, He, NH3, NO, N2O, NO2, O2, SF6, SO2, other components on request
  • Emission monitoring according to EN 15267 and process gas measurements, including in potentially explosive atmospheres
  • Emission monitoring of very low concentrations
  • Measurement of smallest concentrations of NO, NO2, and SO2
  • NOx monitoring by direct measurement of NO and NO2
  • Measurement of sulfur compounds in process gases
  • CO monitoring for explosion protection
  • Measurement of smallest concentrations in hydrogen or hydrocarbons

Cold-dry Extractive gas analyzers

Extractive gas analyzers S710

  • Extractive gas analyzers S700
  • Measured values: Ar, CBrF3, CClF3, CCl2F2, CCl3F, CHClF2, CHCl3, CH2Cl2, CH2O, CH3Cl, CH3OH, (CH3)2O, CH4, CO, CO2, CS2, C2Cl2F4, C2Cl3F3, C2Cl4, C2HCl3, C2H2, C2H2Cl2, C2H2F4, C2H3Cl3, C2H4, C2H4Cl2, C2H5OH, C2H6, C3H4, C3H6, C3H7OH, C3H8, C3H8O2, C4H6, C4H8, C4H10, C4H8O, C4H9OH, C5H12, C6H10O, C6H12, C6H14, C7H16, C7H8, C8H10, He, H2, H2O, NH3, NO, N2O, O2, SF6, SO2
  • S710 19" rack for analyzer cabinets and standard applications
  • S715 wall-mounting enclosure for harsh application conditions and zone 2 explosive environment (ATEX)
  • S720 flame-proof housing for zone 1 explosive environment (ATEX)