Alarm Unit SR336 INOR; Alarm Unit with RTD Input and Double Relay Outputs; RTD sensor or resistance: Pt, Ni, Cu, KTY and further RTDs and resistance; SPDT relays with up to 6 A switch capacity
Online support

Alarm Unit SR336 INOR; Alarm Unit with RTD Input and Double Relay Outputs; RTD sensor or resistance: Pt, Ni, Cu, KTY and further RTDs and resistance; SPDT relays with up to 6 A switch capacity

Input 
RTD sensor or resistance Pt, Ni, Cu, KTY and further RTDs and resistance
Input ranges 0 … 300 Ω / 0 … 3 kΩ (switchable)
Sensor connection 2-wire sensor connection, manual compensation of
line resistances required
Output, Relay 1 & 2
Relay contacts Two isolated 1-pole relays (SPDT), with synchro­nous switching and functions
Contact rating 250 VAC / 6 A, 1500 VA | 250 VDC / 0.2 A, 115 VDC / 0.3 A, 30 VDC / 6 A
Relay function Monostable, Open/Closed-Circuit Operation (switch selectable)
Alarm function High/Low alarm (switch selectable)
Adjustable alarm set-point 0 … 110 % of input range (with 12-turn potentiometer)
Adjustable hysteresis 0 to 6 % or 0 to 60 % of input range (switchable, adjustable with potentiometer)
Status indication Yellow LED
Operation temperature -20 °C to + 60 °C (-4 to +140 °F)
Input / power supply / relay outputs Test Voltage: 4 kV AC, 50 Hz, 1 min.
Working voltage: 1 kV AC/DC for OVC II, 600 V AC/DC for OVC III acc. to DIN EN 61010
Relay 1 / Relay 2 Test Voltage: 3 kV AC, 50 Hz, 1 min. | Working Voltage: 300 V AC/DC
Power Supply 24 V DC, ± 15 %, approx. 0.7 W
Typical accuracy Trip point: < 0.2 % full scale
Mounting 35 mm DIN rail acc. to EN 60715

🔗 View all INOR products at AUMI »»»

🔗 Official INOR website »»»

At a glance

  • Alarm Unit with RTD Input and Double Relay Outputs
  • SR336 is an alarm unit with programmable alarm functions designed for temperature monitoring with RTD sensors in 2-wire sensor connection in the process industry.
  • Two output relays with synchronous switching are available with functions such as MIN/MAX alarm in open-circuit or closed-circuit operation.
  • LEDs in the front indicates alarm state and correct power supply.

Features

  • Input from any RTD sensor or resistance signal in 2-wire sensor connection
  • Selectable input ranges 0-300 ohm or 0- 3 000 ohm
  • Two relay outputs with synchro­nous switching and functions
  • Monostable relays for safe tripping at power failure
  • SPDT relays with up to 6 A switch capacity
  • The switching point and the switching hysteresis are set with potentiometers from the front
  • Relay functions are set with DIP switches from the front
  • Front LEDs for monitoring states and power supply monitoring
  • High 4-port isolation
  • Protective separation acc. to DIN EN 61140 by reinforced insulation acc. to DIN EN 61010
  • 24 V DC power supply
  • Mounted on a standard 35 mm DIN-rail