Technical Specifications:
| Group | Parameter | Value / Description |
| Safety | Device type | Type 4 (IEC 61496-1 / IEC 61496-2) |
| Safety integrity level | SIL 3 (IEC 61508) | |
| Category | Category 4 (EN ISO 13849-1) | |
| Performance Level | PL e (EN ISO 13849-1) | |
| Mission time (TM) | 20 years | |
| Optics | Resolution | 14 mm / 20 mm / 30 mm / 40 mm |
| Scanning range | 10 m / 21 m (depending on resolution and model) • 14 mm: max. 10 m • 20 / 30 / 40 mm: max. 21 m | |
| Protective field height | 300 – 1,800 mm | |
| Wavelength | 850 nm (infrared) | |
| Synchronization | Optical synchronization (no connection cable required between sender and receiver) | |
| Electrical | Supply voltage (VS) | 24 V DC (19.2 – 28.8 V DC) |
| Safety outputs (OSSD) | 2 × PNP semiconductor outputs, short-circuit protected, max. 500 mA per channel | |
| Response time | From ~9 ms (depending on configuration, number of beams, beam coding and cascading) | |
| Connection | System connection | Hirschmann M26 × 11 + FE (12-pin) |
| Maximum cable length | 50 m | |
| Configuration connection | M8 × 4-pin (for PC connection via CDS software) | |
| Mechanical | Housing cross-section | 48 × 40 mm |
| Housing material | Extruded aluminum profile | |
| Environment | Enclosure rating | IP65 (EN 60529) |
| Operating temperature | 0 °C to +55 °C | |
| Storage temperature | –25 °C to +70 °C | |
| Humidity | 15 % – 95 % (non-condensing) |