2D LiDAR Sensor TIM310-1030000S02 SICK – 4 m 270° NPN Output for Area Monitoring
Overview:
The TIM310-1030000S02 is a 2D laser scanning LiDAR sensor from SICK’s TiM3xx series. It offers a detection range of up to 4 m with a 270° scanning angle. The device features 3 NPN digital outputs and supports 16 field triples (48 fields), making it suitable for area monitoring, presence detection, and process control in indoor industrial environments.
Product Overview of the 2D LiDAR Sensor TIM310-1030000S02 SICK
The TIM310-1030000S02 is designed for industrial automation applications that require reliable area monitoring. It utilizes HDDM+ technology to deliver stable detection performance at short to medium distances. The compact design (60 × 60 × 79 mm, 150 g), IP65 protection rating, and Micro-USB interface enable easy configuration and seamless integration into NPN PLC systems, conveyor lines, automatic doors, and industrial machinery. The sensor supports flexible configuration of multiple independent monitoring zones.
Key Features:
- Working range: 0.05 m – 4 m (2 m scanning range at 10% remission)
- Horizontal scanning angle: 270°
- Digital outputs: 3 (NPN, plus 1 × “Device Ready”)
- Protection rating: IP65, weight: 150 g
- Field evaluation: 16 field triples (48 fields), configurable via Micro-USB
Technical Specifications – TIM310-1030000S02 SICK
| Parameter |
Value |
| Model |
TIM310-1030000S02 |
| Part Number |
1062221 |
| Application |
Indoor |
| Measurement principle |
HDDM+ |
| Light source |
Infrared (850 nm) |
| Laser class |
1 (IEC 60825-1:2014, EN 60825-1:2014+A11:2021) |
| Scanning angle (horizontal) |
270° |
| Angular resolution (horizontal) |
1° |
| Scanning frequency |
15 Hz |
| Working range |
0.05 m … 4 m |
| Scanning range at 10% remission |
2 m |
| Supply voltage |
9 V DC … 28 V DC |
| Power consumption |
Typ. 4 W, 16 W (with 4 digital outputs at maximum load) |
| Output current |
≤ 100 mA |
| Digital inputs |
4 |
| Digital outputs |
3 (NPN, additional 1 x “Device Ready”) |
| Interface |
USB (Micro USB) |
| Response time |
1 scan, typ. 67 ms 2 scans, ≤ 134 ms (1) |
| Systematic error |
± 40 mm |
| Statistical error |
< 30 mm |
| Number of monitoring fields |
16 field triples (48 fields, 1 triple configurable directly at the device) |
| Simultaneous monitoring scenarios |
1 (3 fields) |
| Protection rating |
IP65 (IEC 60529:1989+AMD1:1999+AMD2:2013) |
| Operating temperature |
–10 °C … +50 °C |
| Storage temperature |
–30 °C … +70 °C |
| Connection |
1 × 15-pin D-sub HD male connector (0.9 m) |
| Housing color |
Light blue (RAL 5012) |
| Dimensions (D × W × H) |
60 mm × 60 mm × 79 mm |
| Weight |
150 g (without connecting cable) |
| Ambient light immunity |
80,000 lx |
| MTBF |
> 100 years |
| MTTFd |
100 years |
| Certifications |
EU/UK/ACMA CoC, China RoHS, cTUVus, Regulation EU 2023/2854 |
Note (1): Within the working range from +45° to +225°; maximum 150 ms in the working range from –45° to +45°.
Source: SICK Data Sheet TIM310-1030000S02 (Part No. 1062221), updated 12/03/2026. Download datasheet link.
Applications of the TIM310-1030000S02 in Industry
- Production area monitoring: Detection of personnel, pallets, or materials in work zones.
- Conveyor control: Product detection on production lines and activation of control signals.
- Industrial doors and automatic gates: Monitoring the area in front of doors for open/close control.
- Packaging machines and small automation systems: Object detection in confined installation spaces.
- Indoor warehouse monitoring: Creation of multiple flexible monitoring fields for process control.
Important Note: The TIM310-1030000S02 is not a safety laser scanner and must not be used for personnel protection functions according to SIL or PL standards.
Comparison: TIM310-1030000S02 vs. TIM310-1130000
| Criteria |
TIM310-1030000S02 |
TIM310-1130000 |
| Part Number |
1062221 |
1056550 |
| Digital Outputs |
3 (NPN, additional 1 x “Device Ready”) |
3 (PNP, additional 1 x “Device Ready”) |
| Connector Type |
1 x 15-pin D-sub HD male (0.9 m) |
1 x M12 12-pin male (0.8 m) |
| Working range |
0.05 m – 4 m |
0.05 m – 4 m |
| Scanning Angle |
270° |
270° |
| Scanning Frequency |
15 Hz |
15 Hz |
| Protection Rating |
IP65 |
IP65 |
| Weight |
150 g (without cable) |
150 g (without cable) |
| Primary Application |
NPN PLC / traditional systems |
PNP PLC / modern systems |
Conclusion:
The TIM310-1030000S02 and TIM310-1130000 share the same hardware platform, HDDM+ measurement technology, detection range, scanning angle, and area monitoring performance. The main differences are the digital output type (NPN vs. PNP) and connector style. Model selection should therefore be based on the PLC input standard, existing wiring architecture, and system integration requirements rather than detection performance.
Frequently Asked Questions (FAQ)
Q1. Is the TIM310-1030000S02 a safety sensor?
No. The TIM310-1030000S02 is a standard laser scanning sensor for general monitoring and object detection. It does not hold safety certifications according to SIL or Performance Level standards.
Q2. What is the maximum detection distance of the TIM310-1030000S02?
The device has a maximum operating range of 4 m. The typical scanning range for objects with 10% remission is 2 m.
Q3. What type of outputs does the TIM310-1030000S02 use?
This model features 3 NPN digital outputs plus 1 Device Ready signal to indicate operational readiness.
Q4. Can the TIM310-1030000S02 be used outdoors?
It is not recommended. The TIM310 series is primarily designed for indoor applications, although it has an IP65 protection rating.
Q5. What is the difference between TIM310-1030000S02 and TIM310-1130000?
Both models offer equivalent performance. The key differences are: • TIM310-1030000S02: NPN outputs, D-Sub HD connector. • TIM310-1130000: PNP outputs, M12 connector.
Contact for Purchasing the 2D LiDAR Sensor TIM310-1030000S02
AUMI – Official SICK Distributor in Vietnam. Full manufacturer warranty, complete CO/CQ documentation, and 24/7 technical support.
📞 Hotline: 0917 991 589 (Hanoi) | 0932 226 100 (Ho Chi Minh City)
📧 Email: [email protected] 🌐 Website: https://aumi.com.vn/
Addresses:
- Hanoi: B44, Villa Lot, Viet Hung Urban Area, Viet Hung Ward
- Ho Chi Minh City: 2nd Floor, HS Building, 260/11 Nguyen Thai Binh, Bay Hien Ward
- Da Nang: 9th Floor, PV Bank Building, No. 2 30-4 Street, Hoa Cuong Ward