Product | Part no. | Special applications | Device type | Switching output | Connection type | Special features |
KTL180-MM4P41ZZZZZ | 6068616 | Printing mark detection, Splice detection, Wafer inspection, Tube positioning | Base unit | PNP | male connector M8, 4-pin | multi-function input, base unit for BUS mode |
KTL180-MF2P41ZZZZZ | 6068620 | Printing mark detection, Splice detection, Wafer inspection, Tube positioning | expansion unit | PNP | male connector M8, 4-pin | multi-function input, no L+/M, expansion unit for BUS mode |
KTL180-ME2P41ZZZZZ | 6068621 | Printing mark detection, Splice detection, Wafer inspection, Tube positioning | expansion unit | NPN | male connector M8, 4-pin | multi-function input, no L+/M, expansion unit for BUS mode |
KTL180-ML4P51ZZZZZ | 6068619 | Printing mark detection, Splice detection, Wafer inspection, Tube positioning | Base unit | NPN | cable with plug M12, 5-pin | multi-function input, base unit for BUS mode |
KTL180-MM4P51ZZZZZ | 6068618 | Printing mark detection, Splice detection, Wafer inspection, Tube positioning | Base unit | PNP | cable with plug M12, 5-pin | multi-function input, base unit for BUS mode |
KTL180-MN4P71ZZZZZ | 6071999 | Printing mark detection, Splice detection, Wafer inspection, Tube positioning | Stand-alone | NPN | Cable open end | multi-function input, stand-alone mode |
KTL180-MP4P41ZZZZZ | 6068612 | Printing mark detection, Splice detection, Wafer inspection, Tube positioning | Stand-alone | PNP | male connector M8, 4-pin | multi-function input, stand-alone mode |
KTL180-ML4P41ZZZZZ | 6068617 | Printing mark detection, Splice detection, Wafer inspection, Tube positioning | Base unit | NPN | male connector M8, 4-pin | multi-function input, base unit for BUS mode |
KTL180-MP4P51ZZZZZ | 6068614 | Printing mark detection, Splice detection, Wafer inspection, Tube positioning | Stand-alone | PNP | cable with plug M12, 5-pin | multi-function input, stand-alone mode |
KTL180-MN4P41ZZZZZ | 6068613 | Printing mark detection, Splice detection, Wafer inspection, Tube positioning | Stand-alone | NPN | male connector M8, 4-pin | multi-function input, stand-alone mode |
KTL180-MN4P51ZZZZZ | 6068615 | Printing mark detection, Splice detection, Wafer inspection, Tube positioning | Stand-alone | NPN | cable with plug M12, 5-pin | multi-function input, stand-alone mode |
Contrast sensors KTL180
- Safe object detection at high machine speeds
- The KTL180 reliably detects contrast differences even at high machine speeds.
- Thanks to its 31.2 kHz switching frequency, a high grayscale resolution and manual switching threshold adjustment, the KTL180 makes for safe object detection.
- The response time of 16 µs ensures stable and accurate detection of contrast differences, for example with print marks, even for high-gloss materials. The sensor can be quickly adjusted to the respective application with the 7-segment display and easy menu guidance.
- Various teach-in processes as well as an integrated job save increase the flexibility during commissioning in a large range of applications with very high process stability.
Categories: Sick, Contrast sensor, Registration sensors
Tags: Sensor, Contrast sensors, MPA, KTL180
At a glance:
- Very high switching accuracy: 31.2 kHz switching frequency for use in ongoing machine processes
- Easy sensor handling: Multi+functional display enables flexible, user+friendly sensor settings
- Safe detection and safe processes: Detection of very small contrast differences and high+gloss materials thanks to high grayscale resolution and manual switching threshold adjustment
- Versatile use: Different teach-in operations for ideal sensor settings in different applications
- Fast format change thanks to job save
- Compact design for use with limited installation space
Features:
- 31.2 kHz switching frequency at a response time of 16 µs
- High dynamic range
- Multi-functional 7-segment display
- Job save for easy format change
- 1-point, 2-point and dynamic teach-in
- Master-slave function
- A wide range of different fibers
Related products
- No supplementary Ethernet gateway required with Ethernet models – lowers costs
- The CLV62x scanner can be used as a multiplexer in any CAN scanner network from SICK – no supplementary multiplexer necessary
- SMART620 code reconstruction technology
- High scanning frequency of up to 1,200 Hz
- IP 65 or IP 69K rated (depending on type)
- Extremely small housing saves installation space, thereby increasing efficiency of the system
- Reduced storage costs, flexible machine design and easier service
- Yellow LED as optical adjustment indicator and output state display
- Green LED acts as a status indicator
- IO-Link and automation functions
- The smart solution for challenging detection tasks
- With the WLL80 opto-electronic fiber optic amplifier, SICK is creating a new generation of amplifiers for the flexible integration of fiber optics in confined spaces.
- The intelligent WLL80 features IO-Link and can make processes even more efficient with various Smart Tasks. Thanks to IP54, it is protected from dust and spray water during operation. Continuous threshold adaptation ensures good performance in the long term with minimal maintenance requirements.
- In addition to a fast response time and high detection range, it is characterized by flexible and user-friendly parameterization via the OLED display or IO-Link. Whether as a single or bus version, the WLL80 is suitable for a wide range of applications thanks to its extensive fiber optics portfolio.
- Simply clever order picking verification
- The PLG is mounted at each storage bay and has an integrated job LED to display pick position. The PLG’s single-sided reflector strip saves space in the bin and reduces damage and installation costs.
- The integrated job LED reduces the order picker’s search time
- Scanning range up to 2 m
Motion control sensors
- Inclination measurement in two axes without mutual interference
- Reliable output signal thanks to configurable digital filter
- High resolution (0.01°) and accuracy (±0.1° typ.)
- Programmable with the PGT-12-Pro