Product | Part no. | Special applications | Device type | Switching output | Connection type | Special features |
KTL180-MM4P41ZZZZZ | 6068616 | Printing mark detection, Splice detection, Wafer inspection, Tube positioning | Base unit | PNP | male connector M8, 4-pin | multi-function input, base unit for BUS mode |
KTL180-MF2P41ZZZZZ | 6068620 | Printing mark detection, Splice detection, Wafer inspection, Tube positioning | expansion unit | PNP | male connector M8, 4-pin | multi-function input, no L+/M, expansion unit for BUS mode |
KTL180-ME2P41ZZZZZ | 6068621 | Printing mark detection, Splice detection, Wafer inspection, Tube positioning | expansion unit | NPN | male connector M8, 4-pin | multi-function input, no L+/M, expansion unit for BUS mode |
KTL180-ML4P51ZZZZZ | 6068619 | Printing mark detection, Splice detection, Wafer inspection, Tube positioning | Base unit | NPN | cable with plug M12, 5-pin | multi-function input, base unit for BUS mode |
KTL180-MM4P51ZZZZZ | 6068618 | Printing mark detection, Splice detection, Wafer inspection, Tube positioning | Base unit | PNP | cable with plug M12, 5-pin | multi-function input, base unit for BUS mode |
KTL180-MN4P71ZZZZZ | 6071999 | Printing mark detection, Splice detection, Wafer inspection, Tube positioning | Stand-alone | NPN | Cable open end | multi-function input, stand-alone mode |
KTL180-MP4P41ZZZZZ | 6068612 | Printing mark detection, Splice detection, Wafer inspection, Tube positioning | Stand-alone | PNP | male connector M8, 4-pin | multi-function input, stand-alone mode |
KTL180-ML4P41ZZZZZ | 6068617 | Printing mark detection, Splice detection, Wafer inspection, Tube positioning | Base unit | NPN | male connector M8, 4-pin | multi-function input, base unit for BUS mode |
KTL180-MP4P51ZZZZZ | 6068614 | Printing mark detection, Splice detection, Wafer inspection, Tube positioning | Stand-alone | PNP | cable with plug M12, 5-pin | multi-function input, stand-alone mode |
KTL180-MN4P41ZZZZZ | 6068613 | Printing mark detection, Splice detection, Wafer inspection, Tube positioning | Stand-alone | NPN | male connector M8, 4-pin | multi-function input, stand-alone mode |
KTL180-MN4P51ZZZZZ | 6068615 | Printing mark detection, Splice detection, Wafer inspection, Tube positioning | Stand-alone | NPN | cable with plug M12, 5-pin | multi-function input, stand-alone mode |
Contrast sensors KTL180
- Safe object detection at high machine speeds
- The KTL180 reliably detects contrast differences even at high machine speeds.
- Thanks to its 31.2 kHz switching frequency, a high grayscale resolution and manual switching threshold adjustment, the KTL180 makes for safe object detection.
- The response time of 16 µs ensures stable and accurate detection of contrast differences, for example with print marks, even for high-gloss materials. The sensor can be quickly adjusted to the respective application with the 7-segment display and easy menu guidance.
- Various teach-in processes as well as an integrated job save increase the flexibility during commissioning in a large range of applications with very high process stability.
Categories: Contrast sensor, Sick, Registration sensors
Tags: Sensor, Contrast sensors, MPA, KTL180
At a glance:
- Very high switching accuracy: 31.2 kHz switching frequency for use in ongoing machine processes
- Easy sensor handling: Multi+functional display enables flexible, user+friendly sensor settings
- Safe detection and safe processes: Detection of very small contrast differences and high+gloss materials thanks to high grayscale resolution and manual switching threshold adjustment
- Versatile use: Different teach-in operations for ideal sensor settings in different applications
- Fast format change thanks to job save
- Compact design for use with limited installation space
Features:
- 31.2 kHz switching frequency at a response time of 16 µs
- High dynamic range
- Multi-functional 7-segment display
- Job save for easy format change
- 1-point, 2-point and dynamic teach-in
- Master-slave function
- A wide range of different fibers
Related products
- The FLG (frame light grid) switching automation light grid is the innovative solution in which the sender and receiver are combined in one housing for the detection of small parts.
- In dynamic operating mode, the FLG performs reject and removal control of workpieces in pressing and punching machines and also supports the packaging process.
- In static operating mode, it can be used for monitoring thread breakage.
- With a monitored area of 200 mm x 250 mm or 200 mm x 120 mm, it allows detection of small parts down to minimum dimensions of 2 mm over a large area.
Glare sensors
- Quick installation via alignment mode
- Integrated key lock reduces the risk of operating errors and tampering
- Sensitivity adjustments increase the system's operational safety
- IO-Link provides easy data access from the PLC
- Quick and easy configuration
- Simple measurement of components with absolute position value
- Micrometer-accurate detection of very small object tolerances
- Fits in all standard C-slots used around the world or in T-slots in conjunction with an adapter, regardless of the gripper and cylinder profile
- 8 switching points via IO-Link
- Dynamic teach-in for up to 3 switching signals
- The ACS36 (singleturn) and ACM36 (multiturn) encoder families have an analog interface with a maximum resolution of up to 3723 steps (for singleturn and multiturn).
- The analog interfaces (current/voltage) offer a low-cost solution for detecting the position and path, and thereby help to reduce overall system costs.
- IP65 protection class
- Operating temperature: –30 °C to +80 °C
- Detection of magnetic lines for line guidance
- The sensor reliably differentiates between up to three lanes
- Resolution 1 mm, repeatability 1 mm
- CANopen, Modbus RTU RS-485
- Rugged aluminum housing
- Easy installation: Thin housing design and different measurement area variants