At a glance:
- The Infralyt N is used for fast, comprehensive analysis of diesel exhaust gases.
- With its own development of a special NDIR bench with high precision, the gases CO, CO2 and HC can be measured in the respective ranges. The integration of electrochemical cells for fast NO, NO2 and O2 measurement allows to take a statement to the actual pollutant level.
- Due to an internalt condensate seperation, no additional accessories and preparations are necessary. All gas components are brought together with the engine rpm and the oil temperature on the display. With this information, the processes and functions of diesel engines with exhaust treatment and pollution are clearly evaluated.
- The big advantage is, that the small size and low weight make the Infralyt N to form a compact unit, which is suitable for both stationary and for mobile use.
Technical data:
Meas. parameter |
Range | Resolution |
Accuracy |
CO |
0 – 2.000 ppm vol or 0 – 10 % vol* |
1 ppm |
± 30 ppm vol … 5 % rel. |
CO2 |
0 – 20 % vol | 0,01 % |
± 0,5 % vol … 5 % rel. |
HC |
0 – 2.000 ppm vol | 1 ppm |
± 10 ppm vol … 5 % rel. |
NO |
0 – 2.500 ppm vol | 1 ppm |
± 30 ppm vol … 5 % rel. |
NO2 |
0 – 500 ppm vol | 1 ppm |
± 10 ppm vol … 5 % rel. |
O2 |
0 – 22 % vol | 0,01 % |
± 0,01 % vol … 5 % rel. |
Oil Temp* |
0 – 170 °C |
1 °C |
|
RPM* |
400 – 8.000 min-1 |
10 min |