FLOWSIC100 system
- Measured values: Volumetric flow a. c., volumetric flow s. c., gas velocity, sound velocity, gas temperature
- Performance-tested measurands: Gas velocity
- Measurement principle: Ultrasonic transit time difference measurement
- Measuring ranges:
Gas velocity: 0 … ± 40 m/s
Certified measuring ranges: Gas velocity 0 … 20 m/s / 0 … 40 m/s
- Repeatability: For v < 2 m/s: ± 0.02 m/s, For v > 2 m/s: ± 1 %
- Accuracy: ± 0.1 m/s (Depending on application)
- Diagnostics functions: Automatic check cycle for zero and span point/ Extended device diagnosis via SOPAS ET software
- Ambient temperature: –40 °C … +60 °C
- Storage temperature: –40 °C … +70 °C
- Conformities:
2001/80/EC (13. BImSchV)
2000/76/EC (17. BImSchV)
27. BImSchV
30. BImSchV
TA-Luft (Prevention of Air Pollution)
EN 15267
EN 14181
EN 1611-2
MCERTS
GOST
- Electrical safety: CE
FLOWSIC100 M
- Gas temperature: –40 °C … +260 °C
- Operating pressure: –100 hPa … 100 hPa
- Nominal pipe size: 0.15 m … 3.4 m
- Dust load: ≤ 1 g/m³ (Depending on measuring path and gas temperature)
- Enclosure rating: IP65 MCU
- Mounting: Installation angle 45° … 60°
- Electrical connection: Power consumption ≤ 40 W
- System components:
2 x FLSE100-M sender/receiver unit
1 x MCU-N control unit
1 x connection unit
2 x Connection cable
2 x flange with tube
FLOWSIC100 H
- Gas temperature: –40 °C … +260 °C
- Operating pressure: –100 hPa … 100 hPa
- Nominal pipe size: 1.4 m … 13 m
- Dust load: ≤ 100 g/m³ (Depending on measuring path and gas temperature; for dry, non-sticky dust)
- Enclosure rating: IP65 MCU
- Mounting: Installation angle 45° … 60°
- Electrical connection: Power consumption ≤ 40 W
- System components:
2 x FLSE100-H sender/receiver unit
1 x MCU-N control unit
1 x connection unit
2 x Connection cable
2 x flange with tube
FLOWSIC100 PR
- Gas temperature: –40 °C … +260 °C
- Operating pressure: –100 hPa … 100 hPa
- Nominal pipe size: ≥ 0.4 m
- Dust load: ≤ 1 g/m³ (Depending on measuring path and gas temperature)
- Enclosure rating: IP65 MCU
- Mounting: Installation angle 45°
- Electrical connection: Power consumption ≤ 40 W
- System components:
1 x FLSE100-PR sender/receiver unit
1 x MCU-N control unit
1 x Connection cable
1 x flange with tube
FLOWSIC100 S
- Gas temperature: –40 °C … +150 °C
- Operating pressure: –100 hPa … 100 hPa
- Nominal pipe size: 0.15 m … 1.7 m
- Dust load: ≤ 1 g/m³ (Depending on measuring path and gas temperature)
- Enclosure rating: IP65 MCU
- Mounting: Installation angle 45° … 60°
- Electrical connection: Power consumption ≤ 40 W
- System components:
2 x FLSE100-S sender/receiver unit
1 x MCU-N control unit
2 x Connection cable
2 x flange with tube
FLOWSIC100 M-AC
- Gas temperature: –40 °C … +450 °C
- Operating pressure: –100 hPa … 100 hPa
- Nominal pipe size: 0.15 m … 3.4 m
- Dust load: ≤ 1 g/m³ (Depending on measuring path and gas temperature)
- Mounting: Installation angle 45° … 60°
- Electrical connection: Power consumption ≤ 75 W
- System components:
2 x FLSE100-MAC sender/receiver unit
1 x MCU-P control unit
1 x connection unit
2 x Connection cable
2 x purge air hose
2 x flange with tube
FLOWSIC100 H-AC
- Gas temperature: –40 °C … +450 °C
- Operating pressure: –100 hPa … 100 hPa
- Nominal pipe size: 1.4 m … 11.3 m
- Dust load: ≤ 100 g/m³ (Depending on measuring path and gas temperature; for dry, non-sticky dust)
- Mounting: Installation angle 45° … 60°
- Electrical connection: Power consumption ≤ 75 W
- System components:
2 x FLSE100-HAC sender/receiver unit
1 x MCU-P control unit
1 x connection unit
2 x Connection cable
2 x purge air hose
2 x flange with tube
FLOWSIC100 PM
- Gas temperature: –40 °C … +450 °C
- Operating pressure: –100 hPa … 100 hPa
- Nominal pipe size: 0.35 m … 2.5 m
- Dust load: ≤ 1 g/m³ (Depending on measuring path and gas temperature)
- Enclosure rating: IP65 MCU
- Mounting: Installation angle 45° … 60°
- Electrical connection: Power consumption ≤ 40 W
- System components:
2 x FLSE100-PM sender/receiver unit
1 x MCU-N control unit
1 x connection unit
2 x Connection cable
2 x flange with tube
2 x purge air hose
1 x purge air unit
FLOWSIC100 PH
- Gas temperature: –40 °C … +450 °C
- Operating pressure: –100 hPa … 100 hPa
- Nominal pipe size: 0.7 m … 8.7 m
- Dust load: ≤ 100 g/m³ (Depending on measuring path and gas temperature)
- Enclosure rating: IP65 MCU
- Mounting: Installation angle 45° … 60°
- Electrical connection: Power consumption ≤ 40 W
- System components:
2 x FLSE100-PH sender/receiver unit
1 x MCU-N control unit
1 x connection unit
2 x Connection cable
2 x flange with tube
2 x purge air hose
1 x purge air unit
FLOWSIC100 PH-S
- Gas temperature: –40 °C … +450 °C
- Operating pressure: –100 hPa … 100 hPa
- Nominal pipe size: 1.4 m … 11.3 m
- Dust load: ≤ 100 g/m³ (Depending on measuring path and gas temperature)
- Enclosure rating: IP65 MCU
- Mounting: Installation angle 45° … 60°
- Electrical connection: Power consumption ≤ 40 W
- System components:
2 x FLSE100-PHS sender/receiver unit
1 x MCU-N control unit
1 x connection unit
2 x Connection cable
2 x flange with tube
2 x purge air hose
1 x purge air unit
MCU-N control unit
- Description: Compulsory control and evaluation unit for volume flow measuring devices without internal cooling
- Ambient temperature: –40 °C … +60 °C
- Enclosure rating: IP65
- Analog outputs: 1 output 0/2/4 … 20 mA, + 750 Ω, Electrically isolated, up to five outputs when add-on modules are used (option)
- Analog inputs: 2 inputs 0 … 20 mA, Up to four outputs when using additional modules (option)
- Digital outputs : 5 relay outputs (change-over contacts), potential-free, + 48 V, 1 A, Safety extra-low voltage; for status signals “operation/malfunction”, “limit value”, “warning”, “maintenance” and “check cycle”
- Digital inputs: 4 potential-free contacts
- USB:✔, Connection to SOPAS ET software
- Serial:✔, RS-232/ RS-485, Connection to SOPAS ET software, Internal system bus
- Ethernet:✔,Via optional interface module
- Modbus:✔, ASCII RS-485 (via optional interface module), RTU RS-485 (via optional interface module), TCP (via optional interface module)
- PROFIBUS DP:✔,Via optional interface module
- Indication: LC display (option)
- Status LEDs: “Power,” “Failure,” and “Maintenance request”
- Operation: Via LC-display (option) or software SOPAS ET
- Dimensions (W x H x D): 210 mm x 340 mm x 120 mm
- Weight: ≤ 3.7 kg
- Electrical connection:
Voltage: 90 … 250 V, Version with 24 V DC available as an option
Frequency: 47 … 63 Hz
Power consumption: ≤ 15 W
- Options: Interface module(s)/ I/O module(s)/ LC display/ 19″-type
MCU-P control unit
- Description: Compulsory control and evaluation unit with integrated cooling air unit, for volume flow measuring devices with internal cooling
- Ambient temperature: -40 °C … +45 °C, Intake temperatures for purge air
- Enclosure rating: IP54
- Analog outputs: 1 output 0/2/4 … 20 mA, + 750 Ω, Electrically isolated, up to five outputs when add-on modules are used (option)
- Analog inputs: 2 inputs 0 … 20 mA, Not electrically isolated; additional inputs if using I/O modules (option)
- Digital outputs : 5 relay outputs (change-over contacts), potential-free, + 48 V, 1 A, Safety extra-low voltage; for status signals “operation/malfunction”, “limit value”, “warning”, “maintenance” and “check cycle”
- Digital inputs: 4 potential-free contacts
- USB:✔, Connection to SOPAS ET software
- Serial:✔, RS-232/ RS-485, Connection to SOPAS ET software, Internal system bus
- Ethernet:✔, Via optional interface module
- Modbus:✔, ASCII RS-485 (via optional interface module), RTU RS-485 (via optional interface module), TCP (via optional interface module)
- PROFIBUS DP:✔ , Via optional interface module
- Indication: LC display (option)
- Status LEDs: “Power,” “Failure,” and “Maintenance request”
- Operation: Via LC-display (option) or software SOPAS ET
- Dimensions (W x H x D): 300 mm x 455 mm x 220 mm
- Weight: ≤ 13.5 kg
- Electrical connection:
Voltage: 90 … 250 V, Version with 24 V DC available as an option
Frequency: 47 … 63 Hz
Power consumption: ≤ 70 W
- Auxiliary connections: Purge air
- Options: Interface module(s)/ I/O module(s)/ LC display/ 19″-type
SLV4-2 purge air unit, 2BH1300, 3-ph
- Description: Obligatory purge air unit for purged volume flow measuring devices
- Purge air quantity: ≥ 48 m³/h
- Diagnostics functions: Low pressure controller
- Ambient temperature: –20 °C … +40 °C
- Enclosure rating: IP54
- Dimensions (W x H x D): 550 mm x 550 mm x 258 mm (for details see dimensional drawings)
- Weight : 18 kg
- Auxiliary connections Purge air: 40 mm
- Integrated components: 2-step air filter, type Europiclon, dust capacity 200 g