At a glance:
- Gas flow measuring instruments FLOWSIC100
- Rugged titanium converters for long service life
- Corrosion-resistant material for use with aggressive gases (option)
- Integrated measurement via duct diameter for types H, M, and S
- Probe version PR for cost-saving, single-sided installation in duct
- No purge air required for applications with gas temperatures up to 260 °C
Please note: The exact device specifications and performance data of the product may deviate from the information provided here, and depend on the application in which the product is being used and the relevant customer specifications
Technical data:
FLOWSIC100 system
- Measured values: Volumetric flow a. c., volumetric flow s. c., gas velocity, sound velocity, gas temperature
- Performance-tested measurands: Gas velocity
- Measurement principle: Ultrasonic transit time difference measurement
- Measuring ranges:
Gas velocity: 0 … ± 40 m/s
Certified measuring ranges: Gas velocity 0 … 20 m/s / 0 … 40 m/s
- Repeatability: For v < 2 m/s: ± 0.02 m/s, For v > 2 m/s: ± 1 %
- Accuracy: ± 0.1 m/s (Depending on application)
- Diagnostics functions: Automatic check cycle for zero and span point/ Extended device diagnosis via SOPAS ET software
- Ambient temperature: –40 °C … +60 °C
- Storage temperature: –40 °C … +70 °C
- Conformities:
2001/80/EC (13. BImSchV)
2000/76/EC (17. BImSchV)
27. BImSchV
30. BImSchV
TA-Luft (Prevention of Air Pollution)
EN 15267
EN 14181
EN 1611-2
MCERTS
GOST
- Electrical safety: CE
Dimensions:
Connection diagram: