- Type: Rail-mounted
- Input: RTD; Thermocouple
- Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input Thermocouple: Type B, C, E, J, K, L, N, R, S, T, U
- Type Of Transmitter: Digital
- Output: 4-20 mA
- Isolation: Unisolated
- Measuring channels: 1 channel
- Sensor connection: 3-, 4-wire connection
- Power supply: 8 to 32 VDC
- Typical accuracy: 0.15% of span
2-wire transmitter MinIPAQ-L
- Type: Rail-mounted
- Input: RTD; Thermocouple
- Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input Thermocouple: Type B, C, E, J, K, L, N, R, S, T, U
- Output: 4-20 mA
- Isolation: Unisolated
- Measuring channels: 1 channel
- Sensor connection: 3-, 4-wire connection
- Typical accuracy: 0.15% of span
Category: 2-wire Transmitters
Tag: test
At a glance:
- Basic Programmable 2-wire Transmitter
- MINIPAQ-L is a basic, programmable non-isolated, easy-to-use 2-wire transmitter. Configuration is made in seconds with the user friendly Windows software. No external power supply required for configuration.
- MINIPAQ-L is programmable for RTD’s in 3- and 4-wire connection according to different standards as well as for 11 T/C types.
- Useful error correction functions improve the accuracy.
- Accepts RTD in 3- and 4-wire connection and 11 T/C types
- Temperature linear output
- Sensor error and system (sensor/transmitter) error correction for
- highest total accuracy
- Configuration without external power
- Easy-to-use Windows configuration software
- NAMUR compliant
- Test output without breaking the loop
- USB communication
- Withstands vibrations up to 10 g
Technical data:
- Type: Rail-mounted
- Input: RTD; Thermocouple
- Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input Thermocouple: Type B, C, E, J, K, L, N, R, S, T, U
- Type Of Transmitter: Digital
- Output: 4-20 mA
- Isolation: Unisolated
- Measuring channels: 1 channel
- Sensor connection: 3-, 4-wire connection
- Power supply: 8 to 32 VDC
- Typical accuracy: 0.15% of span
Dimensions:
Connection diagram:
You can download more at the document here: Download
Related products
Transmittance dust Measuring Devices
- The DUSTHUNTER T200 is a measuring device for dust at medium to high concentrations
- For medium to high dust concentrations
- Emissions monitoring at power plants and waste incineration plants
- Monitoring of filter systems
- Monitoring of dust load in factory halls
- Control of fresh air and exhaust air units
2-wire Transmitters
- Type: Rail-mounted
- Input: RTD, TC, mV, ohm
- Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input thermocouple: Type B, C, D, E, J, K, N, R, S, T
- Output: 4-20 mA, HART protocol
- Galvanic isolation: 1500 VAC
- Measuring channels: 1 channel
- Sensor connection: 2-, 3-, 4-wire connection
Scattered light dust Measuring Devices
- The FWE200DH dust measuring device is designed to continuously measure dust concentrations in wet flue gas
- For very low to medium dust concentrations
- Gas sampling and return combined in one probe
- Contamination check
- Monitoring of wet gas scrubbing facilities
- Measurement in saturated gas downstream of desulfurization plants
- Determination of dust concentrations in wet exhaust air and in technological processes
2-wire Transmitters
- Type: Rail mounted
- Input: Pt100, Pt1000
- Type of transmitter: Digital
- Output: 4-20 mA
- Measuring range: –200…+850 °C / -328…+1562 °F
- Typical accuracy: Max. ±0,15 K or ±0,15 % of span
- Configuration: App INOR Connect*
- Wireless communication: NFC®
2-wire Transmitters
- Type: Head mounted
- Input: RTD
- Input RTD: Pt100
- Type of transmitter: Digital
- Output: 4-20 mA
- Isolation: Unisolated
- Measuring channels: 1 channel
- Sensor connection: 3-wire connection