Level sensor

Level sensors LFV300

  • Measurement principle: Vibrating level switch
  • Medium: Fluids
  • Process temperature: –50 °C ... +250 °C, See safety notes for ATEX devices
  • Output signal: Non-contact switch/ Double relay (DPDT)/ 1 x PNP/NPN/ NAMUR signal
  • Immune to deposit formation
  • Hygienic designs according to EHEDG and FDA, compatible for CIP and SIP
  • ATEX approval available

Level sensor

Level sensors LBV301

  • Measurement principle: Vibrating level switch
  • Medium: Bulk solids
  • Process temperature: –50 °C ... +250 °C, Temperature range with temperature adapter, detection of solids in water, Temperature adapter
  • Output signal: Non-contact switch/ Double relay (DPDT)/ 1 x PNP/NPN/ NAMUR signal
  • ATEX certifications (1D/2D/1G/2G) available

Level sensor

Level sensors UP56

  • Measurement principle: Ultrasonic sensor
  • Medium: Fluids, bulk solids
  • Measurement: Switch, Continuous
  • Process temperature: –25 °C ... +70 °C
  • Output signal: 1 x PNP + 4 mA ... 20 mA / 0 V ... 10 V/ 2 x PNP/ 2 x NPN/ Push-pull: PNP/NPN; IO-Link 1.1
  • Converter protected by PVDF cover for increased resistance
  • 3-in-1: Continuous measurement, switching signal, and display

  • Measurement principle: Ultrasonic sensor
  • Medium: Fluids
  • Measurement: Switch, Continuous
  • Process temperature: –25 °C ... +85 °C
  • Output signal: 1 x PNP + 4 mA ... 20 mA / 0 V ... 10 V/ 4 mA ... 20 mA/ 4 mA ... 20 mA, 2-wire
  • Non-contact measurement in immersion pipe of up to 1,500 mm
  • PTFE-coated membrane and GF D40 process connection made of PTFE

Pressure sensor

Pressure sensors PAC50

  • Device type: Pressure switch
  • Measuring ranges: –1 bar ... 0 bar; –1 bar ... +1 bar; 0 bar ... +6 bar; 0 bar ... +10 bar; –1 bar ... 10 bar (Gauge pressure)
  • Accuracy: ≤ ± 1.5 % of the span
  • Output signal: Configurable switching outputs PNP, NPN or push-pull analog output signal plus optional IO-Link
  • Bi-color display (green/red) clearly shows the status of the output signal (within or outside the target range)
  • Measuring range for gauge pressure (vacuum and overpressure)

Pressure sensor

Pressure sensor PHT

  • Device type: Pressure transmitter
  • Measuring ranges

Gauge pressure: 0 bar ... 0.25 bar up to 0 bar ... 25 bar

Absolute pressure: 0 bar ... 0,25 bar up to 0 bar ... 16 bar

Compound pressure: –1 bar ... 0 bar up to –1 bar ... +15 bar

  • Accuracy: ≤ ± 0.25 % of the span/ ≤ ± 0.5 % of the span
  • Output signal: Analog
  • Bi-color display (green/red) clearly shows the status of the output signal (within or outside the target range)

Pressure sensor

Pressure sensors PBT

  • Device type: Pressure transmitter
  • Measuring ranges

Gauge pressure: 0 bar ... 0.05 bar up to bar ... 1000 bar

Absolute pressure: 0 bar ... 0.1 bar up to 0 bar ... 25 bar

Compound pressure: –1 bar ... 0 bar up to –1 bar ... +24 bar

  • Accuracy: ≤ ± 1 % of the span/ ≤ ± 0.5 % of the span/ ≤ ± 0.25 % of the span/ ≤ ± 0.6 % of the span
  • Output signal: Analog 4 mA ... 20 mA, 0 V ... 5 V or 0 V ... 10 V

Temperature sensor

Temperature sensors TBS

  • Measuring ranges –20 °C ... +120 °C
  • Pt1000 element, accuracy class A (IEC 60751)
  • Accuracy of sensor element: ≤ ± (0.15 °C + 0.002 |t|)
  • Very reliable: splash-proof housing, high-grade materials, rugged design, and field-proven technology
  • Individually programmable transistor outputs PNP or NPN, optional analog output 4 mA ... 20 mA or 0 V ... 10 V

Temperature sensor

Temperature sensors TBT

  • Well-proven temperature measurement
  • Measuring range: –50 °C +150 °C/ –50 °C +250 °C
  • Accuracy of sensor element: Class A according to IEC 60751
  • Accuracy of the opt. measuring transducer: ≤ ± 0.1 % of span
  • Signal outputs and maximum ohmic load RA: Pt100, 4-wire, 4 mA ... 20 mA, 2-wire (RA ≤ (L+ – 10 V) / 0.028 A [Ohm])
  • Electrical connection: Cable gland M16 x 1.5, IP65/ Cable gland M16 x 1.5, IP67

Wire encoders

Encoder EcoLine

  • Measuring range: 0 m ... 10 m
  • Resolution: 0.001 mm ... 0.14 mm
  • Communication interface: IO-Link / IO-Link V1.1 / COM3 (230,4 kBaud)/ CANopen/ SSI/ PROFINET/ EtherCAT®/ EtherNet/IP™/ DeviceNet™/ PROFIBUS DP/ 4...20 mA/ 0...10 V/ Incremental / TTL / RS-422/ Incremental (HTL / Push pull)/ Incremental (TTL / HTL)
  • Very small, slim housing (55 mm ... 190 mm) with spring integrated in the measurement drum

Incremental encoders

Incremental encoders DLS40

  • Pulses per revolution: 0 … 1024
  • Mechanical design: Solid shaft, face mount flange
  • Shaft diameter: 6 mm
  • Communication interfaces: TTL / RS-422, HTL / Push pull, and Open Collector

Incremental encoders

Incremental encoders DBS36 Core

  • Pulses per revolution: 0 … 2,500
  • Mechanical design: Solid shaft, Servo flange/ Solid shaft, face mount flange/ Blind hollow shaft
  • Shaft diameter: 6 mm feather key groove/ 6 mm/ 1/4"/ 8 mm
  • Communication interfaces: TTL/RS-422, HTL/push pull, Open Collector
  • Temperature range: –20 °C ... +85 °C
  • Enclosure rating: IP65