• Reliable and cost-optimized solution for door locking
  • Increased productivity thanks to the rugged design and protection of the sensor
  • Flexible mounting: Bolt can be used for right- or left-hinged doors
  • Horizontal installation tolerance of 27 mm
  • Compensation of vertical door offset up to ± 7 mm

  • Fast diagnostics via LED status indicator
  • High reliability and precise switching behavior due to proven ASIC technology
  • Safe, direct connection to a safe control solution by means of OSSDs
  • Increased response ranges: 4 mm to 15 mm
  • Temperature range: –25 °C to +70 °C

  • Plus/minus buttons for additional control of direction of movement
  • Different cable lengths available to meet customer application requirements
  • Variant with additional plus/minus buttons
  • Complies to the standard IEC/EN 60947-5-8

Safety locking devices

Safety locking devices I10 Lock

  • Safe and economical door monitoring with high locking force
  • Type: Type 2, electro-mechanical (EN ISO 14119)
  • Type of output: Electro-mechanical contacts
  • Locking principle: Power to lock / power to release
  • Locking monitoring: ✔
  • Door monitoring: ✔
  • Locking force Fmax: 1,300 N (EN ISO 14119)
  • Connection type: Cable gland, 3 x M20/ Plug connector, M12, 8-pin
  • IP 67 enclosure rating

Safety locking devices

Safety locking devices I110 Lock

  • Safe and economical door monitoring with high locking force
  • Type: Type 2, electro-mechanical (EN ISO 14119)
  • Actuator coding level: Low coding level (EN ISO 14119)
  • Locking principle: Power to lock / power to release
  • Locking monitoring: ✔
  • Door monitoring: ✔
  • Locking force Fmax: 2,500 N (EN ISO 14119) 1)
  • Connection type: Cable gland, 3 x M20/ Plug connector, M12, 8-pin

  • Switch type: Safety position switches
  • Number of positive action N/C contacts: 2
  • Number of N/O contacts: 1
  • Enclosure rating: IP66 (IEC 60529)
  • Switching principle: Slow action switching element
  • Approach speed: 0.1 m/min ... 15 m/min

  • Switch type: Safety position switches
  • Number of positive action N/C contacts: 2
  • Number of N/O contacts: 1
  • Housing material: Plastic
  • Enclosure rating: IP66 (IEC 60529)
  • Switching principle: Slow action switching element
  • Approach speed: 0.1 m/min ... 15 m/min
  • Type: Type 1 (EN ISO 14119)

Safety relay

Safety Relay Rely

  • Applications: Evaluation unit / output expansion module for OSSDs / evaluation unit for stop category 1 applications
  • Safety integrity level: SIL3 (IEC 61508)/ SILCL3 (IEC 62061)
  • Category: Category 4 (ISO 13849-1)
  • Performance level: PL e (ISO 13849-1)
  • Solenoid operating voltage: 24 V DC (16.8 V ... 30 V)
  • Sensor monitoring: Discrepancy monitoring/ Cross-circuit detection/ Sequence monitoring

  • Switch type: Rope pull switch
  • Number of positive action N/C contacts: 2 / 3
  • Number of N/O contacts: 2 / 0 / 1
  • Housing material: Metal
  • Enclosure rating: IP66 (IEC 60529)

Safety command devices

Emergency stop pushbutton ES21

  • Switch type: Emergency stop pushbutton
  • Number of positive action N/C contacts: 1 / 2 / 3
  • Number of N/O contacts: 0 / 1
  • Emergency stop pushbutton (illuminable): – / ✔
  • Enclosure rating: IP65 (IEC 60529)/ IP54 (IEC 60529)
  • Connection type: Cable gland, 2 x M20
  • Housing material: Plastic

Safety multibeam scanners

Safe multibeam scanners ScanGrids2

  • Worldwide revolutionary safety solution for line-guided small vehicles
  • Save space when integrating into your AGCs
  • Safety level: Type 2, PL c, SIL1, SILCL1
  • Warning field range: 4 m
  • Scanning angle: 150°
  • Resolution (can be configured): 50 mm, 70 mm, 150 mm, 200 mm