At a glance:
- Safe and economical door monitoring with high locking force
- Improved diagnostics due to additional contacts for door monitoring
- Different switching elements offer the appropriate solution for electrical installation
- Narrow plastic housing
- Metal actuator head
- Power to lock or power to release variants
- Lock and door monitoring
Technical data:
- Type: Type 2, electro-mechanical (EN ISO 14119)
- Actuator coding level: Low coding level (EN ISO 14119)
- Type of output: Electro-mechanical contacts
- Locking principle: Power to lock / power to release
- Locking monitoring: ✔
- Door monitoring: ✔
- Locking force Fmax: 2,500 N (EN ISO 14119) 1)
- Connection type: Cable gland, 3 x M20/ Plug connector, M12, 8-pin
Dimensions:
Connection diagram: