MEASURING DUST EMISSIONS IS EASY

Measuring dust emissions is easy – if one has the right measuring equipment. When it comes to choosing the right measuring device, one has to look at both the properties of the medium to be measured and the environmental conditions

This is where ’s strengths really come into their own – tried-and-tested measurement principles applied in a diverse portfolio of products and combined with decades of experience in thousands of different installations. It is not simply a question of complying with legal requirements. But which measurement technology is best? Which device version is most suited to the task at hand?
When  it  comes  to  a  certain aspect, all measurement technicians only want one thing: rugged measuring devices that provide accurate and  fast  measurements  with a high  level of availability. The more detailed the description of the task at hand, the easier it is to provide a safe and cost-effective  measurement.  And  this  does  not  just  apply  to  the  initial  investment  costs,  it  applies for the device’s entire operating  life. Whether it is used for dry, corrosive, or hot flue gases. Whether it is used in  process  control  for  measuring  moist  emissions, for the smallest concentration  of dust following fabric and bag filters, or  for high concentrations of dust in raw gas  prior to electric filters. For personal and  occupational  safety  purposes,  fine  dust  with  particle  sizes  in  the  low  µm  range  have to be monitored in the air in production halls. SICK’s dust measuring devices can even provide effective and accurate measurements for the excessive development of dust by grinders in quarries.

Environmental standards are becoming more stringent, often requiring companies to measure low concentrations of dust. This task requires a particularly sensitive measuring process. Ever since Erwin Sick conducted his pioneering work in 1956, SICK has been concentrating on optical measurement processes. The scattered light approach provides the best foundation for recording even the lowest concentration of dust. This also applies for more demanding applications in hot or aggressive gases with low to medium dust content. The DUSTHUNTER SB50 and SB100 scattered light dust measuring devices apply the backward scattering principle. Installing the devices in a stack is easy: a single opening is enough.

DUSTHUNTER: More flexibility thanks to multiple device versions

Stacks with thicker walls require dust measuring devices to have a special shape without sacrificing any of the measurement accuracy, even for the lowest concentrations of dust. other stacks require the measuring device to be installed in one exceptionally small opening. For these two scenarios, the DUSTHUNTER SP100 comes with a special probe with graduated lengths from 435 to 2,435 mm. The maximum drill hole diameter required is 130 mm. Made from stainless steel, titanium or Hastelloy, the probes are well equipped to withstand hot or corrosive substances. The DUSTHUNTER SP100 also uses the scattered light principle, applying highly sensitive forward scattering. The DUSTHUNTER SF100 is SICK’s solution for particularly difficult cases when it comes to the shape of the stack and the properties of the medium. If the flow is affected by inhomogeneities or swirling in larger channels, it can make representative dust measurement more difficult. The problem can only be solved by taking a measurement across the entire diameter of the stack. The DUSTHUNTER SF100 also uses the scattered light principle (forwards scattering). Its receiver is installed opposite the sender on the other side of the stack, making it the ideal solution for measuring larger diameters. It can even measure the lowest concentration of dust with maximum precision. However, it is also suitable for use with corrosive and hot media. The DUSTHUNTER SF100 makes almost no contact with the medium itself.

Measuring medium or high concentration of dust

Single measurement  across  the  entire  cross  section of the stack quickly records the concentration values. Transmittance also uses a conventional  optical process, making it ideal for measuring medium to high concentrations of  dust: the DUSTHUNTER T50, T100, and T200 transmittance dust measuring devices.  The  DUSTHUNTER  T50  is  all  you  need  to  tackle  simple  measurements.  Like SICK’s measuring devices that use the scattered  light  principle,  the  DUSTHUNTER  T100  includes  an  automatic contamination measurement and correction  function.  It  provides  users  with  an early  warning  should  the  contamination  level on the measurement optics exceed the permitted  limit. The DUSTHUNTER T200 is also equipped with an automatic  self-alignment  function  for  the  optics:  a  unique  feature  only  available  in  SICK products. It corrects any distortion on the optical axis that may occur as a result of  the thermal expansion of the stack. Both functions reduce excessive maintenance cycles. The  automatic self-alignment function also makes it easier to commission the device.

In some processes, exhaust gases are cleaned in scrubber units before they are released. Recording a reliable measurement for dust concentration is particularly difficult when the dust is damp. Conventional dust measuring devices cannot differentiate between specks of dust and drops of water, leading to distorted measurement readings. only one thing can help here: using a bypass system to extract the medium from the stack, dry it, and then measure it. This is the approach applied by the extractive scattered light dust measuring device, the FWE200DH. It extracts flue gas from the stack on a permanent basis, dries it within a few seconds using a thermo cyclone, and records particularly low concentrations of dust accurately using forward light scattering. The FWE200DH features a space-saving design and can therefore be installed straight into the stack. It is equipped with a corrosion-resistant sampling probe made from PVDF.