- Type: Rail-mounted
- Input: RTD; Thermocouple
- Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input Thermocouple: Type B, C, E, J, K, L, N, R, S, T, U
- Type Of Transmitter: Digital
- Output: 4-20 mA
- Isolation: Unisolated
- Measuring channels: 1 channel
- Sensor connection: 3-, 4-wire connection
- Power supply: 8 to 32 VDC
- Typical accuracy: 0.15% of span
2-wire transmitter MinIPAQ-L
- Type: Rail-mounted
- Input: RTD; Thermocouple
- Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input Thermocouple: Type B, C, E, J, K, L, N, R, S, T, U
- Output: 4-20 mA
- Isolation: Unisolated
- Measuring channels: 1 channel
- Sensor connection: 3-, 4-wire connection
- Typical accuracy: 0.15% of span
Category: 2-wire Transmitters
Tag: test
At a glance:
- Basic Programmable 2-wire Transmitter
- MINIPAQ-L is a basic, programmable non-isolated, easy-to-use 2-wire transmitter. Configuration is made in seconds with the user friendly Windows software. No external power supply required for configuration.
- MINIPAQ-L is programmable for RTD’s in 3- and 4-wire connection according to different standards as well as for 11 T/C types.
- Useful error correction functions improve the accuracy.
- Accepts RTD in 3- and 4-wire connection and 11 T/C types
- Temperature linear output
- Sensor error and system (sensor/transmitter) error correction for
- highest total accuracy
- Configuration without external power
- Easy-to-use Windows configuration software
- NAMUR compliant
- Test output without breaking the loop
- USB communication
- Withstands vibrations up to 10 g
Technical data:
- Type: Rail-mounted
- Input: RTD; Thermocouple
- Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input Thermocouple: Type B, C, E, J, K, L, N, R, S, T, U
- Type Of Transmitter: Digital
- Output: 4-20 mA
- Isolation: Unisolated
- Measuring channels: 1 channel
- Sensor connection: 3-, 4-wire connection
- Power supply: 8 to 32 VDC
- Typical accuracy: 0.15% of span
Dimensions:

Connection diagram:

You can download more at the document here: Download
Related products
SALE
Signal isolation
- Input mA: -1 to +50 mA
- Input impedance: 10 Ω
- Adjustments – Zero: Any value within range limits
- Adjustments – Minimum spans: 0,4 mA
- Output: 4-20 / 20-4 mA
- Galvanic isolation: 1500 VAC, 1 min
- Power supply: 7,5 to 36 VDC
- Typical accuracy: ±0,1 % of span
SALE
2-wire Transmitters
- Type: Rail-mounted
- Input: RTD; Thermocouple; Universal
- Input RTD: Pt10, Pt50, Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input Thermocouple: Type B, C, D, E, J, K, N, R, S, T
- Output: 4-20 mA; HART®
- Isolation: Isolated
- Measuring channels: 2 channels
- Sensor connection: 2-, 3-, 4-wire connection
- Approvals: ATEX, IECEx, SIL2
SALE
Signal isolation
- The Bipolar Isolation Amplifier IisPAQ-661 is used for isolation and conversion of bipolar and unipolar industrial standard signals.
- Input Current (calibrated switchable): ±20 mA, 0… 20 mA, 4… 20 mA/ ±10 mA, 0… 10 mA, 2… 10 mA
- Input Voltage (calibrated switchable): ±10 V, 0… 10 V, 2 … 10 V/ ±5 V, 0… 5 V, 1 … 5 V
- Output Current (calibrated switchable): ±20 mA, 0… 20 mA, 4… 20 mA/ ±10 mA, 0… 10 mA, 2… 10 mA
- Output Voltage (calibrated switchable): ±10 V, 0… 10 V, 2 … 10 V / ±5 V, 0… 5 V, 1 … 5 V
SALE
Scattered light dust Measuring Devices
- Measurement independent of gas velocity, humidity and particle charge
- Approved according to EN 15267
- For medium to large duct diameters
- Emission monitoring of power stations and waste incineration plants
- Monitoring of dust concentrations downstream of filter plants
- Monitoring of dust loads in factory workshops
- Control of fresh air supplies and exhaust air plants
SALE
Hot-wet Extractive gas analyzers
- CEMS solutions MCS200HW
- The MCS200HW is a multi-component analyzer system for continuous monitoring of up to 10 IR measurement components in flue gases of industrial combustion plants
- Measured values: CH4, CO, CO2, Corg, HCl, H2O, H2SO4, NH3, NO, NO2, N2O, O2, SO2, SO3
- Emission monitoring for waste incineration plants as well as power plants and plants with co-incineration, e.g. cement plants
- Measurement of nitrogen oxides (NO, NO2, N2O) in nitric acid plants
- SO3 monitoring in coal-fired power plants