Features:
- Application: Indoor area
 - Protective field range: 2 m / 3 m
 - Warning field range: 8 m
 - Scanning angle: 270°
 - Number of fields: 3
 - Number of monitoring cases: 1
 - Response time: 80 ms
 - Integration in the control system: Local inputs and outputs (I/O)/ EFI
 - Configuration method: PC with CDS (Configuration and Diagnostic Software)
 - Performance level: PL d (EN ISO 13849)
 - Enclosure rating: IP65 (EN 60529)
 
Mechanics/ Electronics
- Power supply: 24 V DC (16.8 V DC … 30 V DC)
 - OSSD pairs: 1
 - Inputs (external device monitoring (EDM)): 1 (availability depends on the configuration of the universal I/Os)
 - Inputs (reset/restart): 1 (availability depends on the configuration of the universal I/Os)
 - Inputs (standby): 1
 - Universal I/Os: 5 (Freely programmable, e.g., external device monitoring input, reset input, contamination warning, reset required)
 - Configuration and diagnostic interface: RS-232
 - Measured data output: Via RS-422
 - Connection type: System plug with or without connecting cable
 - Temperature range: –10 °C … +50 °C
 













				
				
				
				
				