Features:
- Application: Indoor area
- Dimensions (W x H x D): 106.6 mm x 80 mm x 117.5 mm (including system plug)
- Protective field range: 3 m
- Warning field range: 10 m
- Scanning angle: 275°
- Resolution (can be configured): 20 mm, 30 mm, 40 mm, 50 mm, 60 mm, 70 mm, 150 mm, 200 mm
- Angular resolution: 0.17°
- Number of fields: 8 / 128
- Number of monitoring cases: 2 / 128
- Response time: ≥ 70 ms
- Performance level: PL d (EN ISO 13849)
- Configuration method: PC with Safety Designer (configuration and diagnostic software)
- Enclosure rating: IP65 (IEC 60529)
Mechanics/ Electronics
- Power supply: 24 V DC (16.8 V DC … 30 V DC)
- OSSD pairs: 1/ 2
- Universal I/O: ¾
- Configuration and diagnostic interface: USB 2.0, micro USB
- Temperature range: –10 °C … +50 °C