At a glance:
- Type 2 (IEC 61496), SIL1 (IEC 61508), PL c (EN ISO 13849), only in conjunction suitable testing device, e.g., Flexi Classic or Flexi Soft
- Compact M30 sensors with ranges up to 60 m
- Radial optics (90° deflector mirror)
- Straightforward diagnostics and service
- Flexible device integration makes it possible to set up individual access protections
- Well suited to withstand extreme ambient conditions such as heat, cold or moisture
Technical data:
- Safety level: Type 2, PL c, SIL1, SILCL1
- Scanning range: 5 m / 10 m / 60 m
- Construction size: M18 / M30
- Supply voltage: 24 V DC (19.2 V DC … 28.8 V DC)
- Enclosure rating: IP67 (EN 60529)
- Ambient operating temperature: –40 °C … +55 °C
Dimensions:
Connection diagram: