- Type: Head mounted
- Input: Pt100, Pt1000
- Type of transmitter: Digital
- Output: 4-20 mA
- Measuring range: –200…+850 °C / -328…+1562 °F
- Sensor error: NAMUR NE43
- Adjustments – Zero point: Any value within range limits
- Adjustments – Minimum span: 20 °C / 36 °F
- Ambient temperature: –40…+85 °C / -40…+185 °F
- Humidity: 0…98% RH (non-condensing)
- Vibration: IEC 60068-2-6,10 g
- EMC: EN 61326-1 and EN 61326-2-3
- Isolation: Unisolated
- Power supply: 6…32 VDC
- Long-term stability: Max. drift ±0,05 % of span/year
- Typical accuracy: Max. ±0,15 K or ±0,15 % of span
- Adjustable filtering level: 0,4 to 26 s
- Configuration: App INOR Connect*
- Wireless communication: NFC®
2-wire transmitter APAQ C130
- Type: Head mounted
- Input: Pt100, Pt1000
- Type of transmitter: Digital
- Output: 4-20 mA
- Measuring range: –200…+850 °C / -328…+1562 °F
- Typical accuracy: Max. ±0,15 K or ±0,15 % of span
- Configuration: App INOR Connect*
- Wireless communication: NFC®
Categories: 2-wire Transmitters, NEW PRODUCTS
At a glance:
- Digital 2-wire transmitter for Pt100 and Pt1000 with wireless communication
- The APAQ C130 is a modern transmitter with high reliability and
- great performance. External influences such as ambient temperature, vibration, moisture and EMC interference have minimal influence on the measurement result, thanks to the robust design.
- What characterizes APAQ C130 is simplicity. You can easily configure the transmitters wirelessly via NFC with your smartphone or tablet. There is no need for expensive configuration tools or fixed workstations for transmitter configuration.
Technical data:
- Type: Head mounted
- Input: Pt100, Pt1000
- Type of transmitter: Digital
- Output: 4-20 mA
- Measuring range: –200…+850 °C / -328…+1562 °F
- Sensor error: NAMUR NE43
- Adjustments – Zero point: Any value within range limits
- Adjustments – Minimum span: 20 °C / 36 °F
- Ambient temperature: –40…+85 °C / -40…+185 °F
- Humidity: 0…98% RH (non-condensing)
- Vibration: IEC 60068-2-6,10 g
- EMC: EN 61326-1 and EN 61326-2-3
- Isolation: Unisolated
- Power supply: 6…32 VDC
- Long-term stability: Max. drift ±0,05 % of span/year
- Typical accuracy: Max. ±0,15 K or ±0,15 % of span
- Adjustable filtering level: 0,4 to 26 s
- Configuration: App INOR Connect*
- Wireless communication: NFC®
Dimensions:
Connection diagram:
You can download more at the document here: APAQ C130
Related products
2-wire Transmitters
- Type: Head-mounted
- Input: RTD, TC, mV, ohm
- Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input thermocouple: Type B, C, D, E, J, K, N, R, S, T
- Output: 4-20 mA
- Galvanic isolation: 1500 VAC
- Measuring channels: 1 channel
- Sensor connection: 2-, 3-, 4-wire connection
- Power supply: IPAQ-C330: 8 to 36 VDC/ IPAQ-C330X: 8 to 30 VDC
2-wire Transmitters
- Type: Rail-mounted
- Input: RTD; Thermocouple
- Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input Thermocouple: Type B, C, E, J, K, L, N, R, S, T, U
- Output: 4-20 mA
- Isolation: Unisolated
- Measuring channels: 1 channel
- Sensor connection: 3-, 4-wire connection
- Typical accuracy: 0.15% of span
Single-Point Lubrication Systems
-
perma FLEX PLUS is a compact, ready-to-use lubrication system supplied as a complete unit.
-
It can be used in various types of applications at temperatures ranging from -20 °C to +55 °C.
-
The discharge period is electronically controlled by the gas generating cells and is freely adjustable in monthly steps.
-
The lubrication point is continuously supplied with fresh lubricant throughout the selected discharge period.
-
perma FLEX PLUS has a boost function to quickly provide fresh lubricant.
2-wire Transmitters
- Type: Rail-mounted
- Input: RTD, Thermocouple, Universal
- Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input Thermocouple: Type B, C, E, J, K, L, N, R, S, T, U
- Output: 4-20 mA
- Isolation: Isolated
- Measuring channels: 1 channel
- Sensor connection: 3-, 4-wire connection
- Approvals: ATEX
- Typical accuracy: ±0.1 % of span
2-wire Transmitters
- Type: Rail-mounted
- Input: RTD, TC, mV, ohm
- Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input thermocouple: Type B, C, D, E, J, K, N, R, S, T
- Output: 4-20 mA
- Galvanic isolation: 1500 VAC
- Measuring channels: 1 channel
- Sensor connection: 2-, 3-, 4-wire connection