When it comes to measuring accuracy and maximum stability of measurement, INOR Process AB (Sweden) set high standard on the market for measurinng accuracy and maximum stability. With more than 75 years experience, Inor has built up a unique competence in temperature measuring. Inor is one of largest.
2-wire Transmitters
- Type: Head mounted
- Input: Pt100, Pt1000
- Type of transmitter: Digital
- Output: 4-20 mA
- Measuring range: –200…+850 °C / -328…+1562 °F
- Typical accuracy: Max. ±0,15 K or ±0,15 % of span
- Configuration: App INOR Connect*
- Wireless communication: NFC®
2-wire Transmitters
- Type: Rail mounted
- Input: Pt100, Pt1000
- Type of transmitter: Digital
- Output: 4-20 mA
- Measuring range: –200…+850 °C / -328…+1562 °F
- Typical accuracy: Max. ±0,15 K or ±0,15 % of span
- Configuration: App INOR Connect*
- Wireless communication: NFC®
2-wire Transmitters
- Type: Head-mounted
- Input: RTD, TC, mV, ohm
- Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input thermocouple: Type B, C, D, E, J, K, N, R, S, T
- Output: 4-20 mA
- Galvanic isolation: 1500 VAC
- Measuring channels: 1 channel
- Sensor connection: 2-, 3-, 4-wire connection
- Power supply: IPAQ-C330: 8 to 36 VDC/ IPAQ-C330X: 8 to 30 VDC
2-wire Transmitters
- Type: Rail-mounted
- Input: RTD, TC, mV, ohm
- Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input thermocouple: Type B, C, D, E, J, K, N, R, S, T
- Output: 4-20 mA
- Galvanic isolation: 1500 VAC
- Measuring channels: 1 channel
- Sensor connection: 2-, 3-, 4-wire connection
2-wire Transmitters
- Type: Head-mounted
- Input: RTD, TC, mV, ohm
- Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input thermocouple: Type B, C, D, E, J, K, N, R, S, T
- Output: 4-20 mA, HART protocol
- Galvanic isolation: 1500 VAC
- Measuring channels: 1 channel
- Sensor connection: 2-, 3-, 4-wire connection
2-wire Transmitters
- Type: Rail-mounted
- Input: RTD, TC, mV, ohm
- Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input thermocouple: Type B, C, D, E, J, K, N, R, S, T
- Output: 4-20 mA, HART protocol
- Galvanic isolation: 1500 VAC
- Measuring channels: 1 channel
- Sensor connection: 2-, 3-, 4-wire connection
TRA Series
- Hygienic compact sensor with flange DN25/38 ISO 2852 clamp connection
- Measuring element: Pt100
- Process temperature: -50…+200°C
- Material: 1.4404 / 316L
- Diameter: 6 mm
- Output: 4...20 mA, temperature linear
- Transmitter accuracy: ±0.15°C or ±0.15% of measuring span
TRA Series
- Measuring element: Pt100
- Process temperature: -50…+200°C
- Process connection: G1/2” thread
- Material: 1.4404 / 316L
- Diameter: 6 mm
- Output: 4...20 mA, temperature linear
- Transmitter accuracy: ±0.15°C or ±0.15% of measuring span
TRA Series
- Measuring element: Pt100
- Process temperature: -50…+200°C
- Process connection: G1/2” thread
- Material: 1.4404 / 316L
- Diameter: 6 mm
- Output: 4...20 mA, temperature linear
- Transmitter accuracy: ±0.15°C or ±0.15% of measuring span
TRA Series
- Measuring element: Pt100
- Process temperature: -30…+350°C
- Process connection: Plugg-in
- Material: 1.4404 / 316L
- Diameter: 3 / 6 mm
- Shape of thermowell: Straight
- Protection class: IP67
TRA Series
- Measuring element: Pt100
- Process temperature: -50…+120°C
- Process connection: Screw-in
- Material: 1.4404 / 316L
- Diameter: 3 mm
- Shape of thermowell: Straight
- Protection class: IP67
2-wire Transmitters
- Type: Head mounted
- Input: RTD
- Input RTD: Pt100
- Type of transmitter: Digital
- Output: 4-20 mA
- Isolation: Unisolated
- Measuring channels: 1 channel
- Sensor connection: 3-wire connection