- Valve Actuation: Solenoid
- Body Material: Aluminum
- Media: Natural Gas
- Pipe / Port Size: 3/4 “; 1 “; 1 1/4 “; 1 1/2 “; 2 “; 2 1/2 “; 3 “
- Port Type: NPTF
- Function: 2 way – 2/2 Normally Closed
- Flow: From 2.0 Cv to 6.0 Cv; From 6.0 Cv to 14.0 Cv; Over 14.0 Cv
- Voltage: 110 AC; 120 AC; 220 AC; 230 AC | 50/60
- Max Differential / Max Operating Pressure: Vacuum to 150 PSIG
- Operating Environment: Indoor, Outdoor
- Standards / Regulations: CSA, FM, Type 1, UL, Type 4
ASCO™ Series 043 Gas Shutoff Valves
- Valve Actuation: Solenoid
- Body Material: Aluminum
- Media: Natural Gas
- The ASCO Series 043 are 2-way, normally closed gas shutoff valves for on-off control of fuel gas in commercial and industrial gas burners.
- Standards / Regulations: CSA, FM, Type 1, UL, Type 4
Category: Fuel, Gas & Oil Valves
Tag: test
At a glance:
- The ASCO Series 043 are 2-way, normally closed gas shutoff valves for on-off control of fuel gas in commercial and industrial gas burners.
- The valves feature a unique double-disc design with over travel that provides redundant sealing for leak-tight operation.
- The Series 043 includes visual position indication and proof of closure.
Features:
- Opening and closing response times are less than 1 second
- Visual indication of open and shut position
- Proof of closure switch rated at 1 amp
- Zero-differential piloted diaphragm
- 1/8-inch NPT upstream and downstream pipe taps with plugs for routine testing
- 5-pound closing spring for high force shut-off
You can download more at the document here: Download
Related products
Hot-wet Extractive gas analyzers
- CEMS solutions MCS100FT
- The FTIR measuring principle allows the simultaneous determination of more than 12 measuring components – tailor-made for the particular requirements of the customer.
- Lowest approved HF measuring range: 0 ... 3 mg/m³
- Automatic spectrum adjustment via AutoVAL for reliable measuring values
- Approved according to EN 15267
- Emission monitoring in waste incineration plants
- Effective HF limit value monitoring, e. g., in aluminum production
- Monitoring of gaseous emissions in cement plants or power stations
Scattered light dust Measuring Devices
- The FWE200DH dust measuring device is designed to continuously measure dust concentrations in wet flue gas
- For very low to medium dust concentrations
- Gas sampling and return combined in one probe
- Contamination check
- Monitoring of wet gas scrubbing facilities
- Measurement in saturated gas downstream of desulfurization plants
- Determination of dust concentrations in wet exhaust air and in technological processes
ELEMENT
- The structure of ELEMET elevator belts is a steel carcass composed by a strong warp of steel cord with suitable elastic modulus such to reach the best compromise between low elongation and good flexibility.
- Rubber covers for elevator belts have two main functions: protection of the carcass against material and moisture aggression, assurance of the perfect bucket holding up without bolt loosening in course of time.
- Superior temperature resistance
2-wire Transmitters
- Type: Rail-mounted
- Input: RTD; Thermocouple
- Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input Thermocouple: Type B, C, E, J, K, L, N, R, S, T, U
- Output: 4-20 mA
- Isolation: Unisolated
- Measuring channels: 1 channel
- Sensor connection: 3-, 4-wire connection
- Typical accuracy: 0.15% of span
General Service Valves
- Valve Actuation: Solenoid
- Body Material: Aluminum
- Media: Air, Inert Gas, Liquid Propane Gas, Natural Gas, Oxygen
- The ASCO Series 214 gas shutoff valves are specifically designed for on-off control of fuel gas in commercial and industrial gas burners.
- Broad ambient range of -40°F to 140°F is ideally suited for frigid and hot environments