- Type: Rail-mounted
- Input: RTD, Thermocouple, Universal
- Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input Thermocouple: Type B, C, E, J, K, L, N, R, S, T, U
- Type of Transmitter: Digital
- Output: 4-20 mA
- Isolation: Isolated
- Measuring channels: 1 channel
- Sensor connection: 3-, 4-wire connection
- Power supply: 8 to 36 VDC
- Approvals: ATEX
- Typical accuracy: ±0.1 % of span
2-wire transmitter IPAQ-21
- Type: Rail-mounted
- Input: RTD, Thermocouple, Universal
- Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input Thermocouple: Type B, C, E, J, K, L, N, R, S, T, U
- Output: 4-20 mA
- Isolation: Isolated
- Measuring channels: 1 channel
- Sensor connection: 3-, 4-wire connection
- Approvals: ATEX
- Typical accuracy: ±0.1 % of span
Category: 2-wire Transmitters
At a glance:
- Universal 1&2-channels programmable 2-wire Transmitter
- IPAQ-21LX is a 1-channel, universal, isolated 2-wire transmitter for Ex-applications.No zener barriers or Ex power supplies are needed, which reduces costs for purchase, design and maintenance.
- IPAQ-21L is a 1-channel version for non-Ex-applications. very costeffective Ex-solution fully universal, linearized and isolated
- Accepts RTD, T/C, mV und Ω
- Sensor error and system (senor/transmitter) error correction for highest total accuracy
- Full acces to all Features while in operation
- NAMUR compliant
- Consistent sensor break function
- Simplified loop Check-up with calibration output
- IPRO, easy-to-use Windows configuration software
- Fixed terminals or plug-in terminals with coding (see ordering Information)
Technical data:
- Type: Rail-mounted
- Input: RTD, Thermocouple, Universal
- Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input Thermocouple: Type B, C, E, J, K, L, N, R, S, T, U
- Type of Transmitter: Digital
- Output: 4-20 mA
- Isolation: Isolated
- Measuring channels: 1 channel
- Sensor connection: 3-, 4-wire connection
- Power supply: 8 to 36 VDC
- Approvals: ATEX
- Typical accuracy: ±0.1 % of span
Dimensions:
You can download more at the document here: Download
Related products
2-wire Transmitters
- Type: Head mounted
- Input: Pt100, Pt1000
- Type of transmitter: Digital
- Output: 4-20 mA
- Measuring range: –200…+850 °C / -328…+1562 °F
- Typical accuracy: Max. ±0,15 K or ±0,15 % of span
- Configuration: App INOR Connect*
- Wireless communication: NFC®
2-wire Transmitters
- Type: Rail mounted
- Input RTD: Pt100
- Type of transmitter: Digital
- Output: 4-20 mA
- Isolation: Unisolated
- Measuring channels: 1 channel
- Sensor connection: 3-wire connection
- Power Supply: Standard version: 6 to 32 VDC
- Typical accuracy: Max. ±0.1K or ±0,1 % of span
2-wire Transmitters
- Type: Rail-mounted
- Input: RTD, TC, mV, ohm
- Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input thermocouple: Type B, C, D, E, J, K, N, R, S, T
- Output: 4-20 mA, HART protocol
- Galvanic isolation: 1500 VAC
- Measuring channels: 1 channel
- Sensor connection: 2-, 3-, 4-wire connection
2-wire Transmitters
- Type: Head-mounted
- Input: RTD, TC, mV, ohm
- Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input thermocouple: Type B, C, D, E, J, K, N, R, S, T
- Output: 4-20 mA
- Galvanic isolation: 1500 VAC
- Measuring channels: 1 channel
- Sensor connection: 2-, 3-, 4-wire connection
- Power supply: IPAQ-C330: 8 to 36 VDC/ IPAQ-C330X: 8 to 30 VDC
2-wire Transmitters
- Type: Head-mounted
- Input RTD: Pt100, Pt1000
- Output: 0-10 V
- Isolation: Unisolated
- Measuring channels: 1 channel
- Input connections: 3-wire connection
- Power supply: 15 to 30 VDC