- Type: Rail mounted
- Input: RTD
- Input RTD: Pt100
- Type of transmitter: Digital
- Output: 4-20 mA
- Isolation: Unisolated
- Measuring channels: 1 channel
- Sensor connection: 3-wire connection
- Power Supply: Standard version: 6 to 32 VDC
- Typical accuracy: Max. ±0.1K or ±0,1 % of span
2-wire transmitter IPAQ R202
- Type: Rail mounted
- Input RTD: Pt100
- Type of transmitter: Digital
- Output: 4-20 mA
- Isolation: Unisolated
- Measuring channels: 1 channel
- Sensor connection: 3-wire connection
- Power Supply: Standard version: 6 to 32 VDC
- Typical accuracy: Max. ±0.1K or ±0,1 % of span
Category: 2-wire Transmitters
At a glance:
- Programmable 2-wire Transmitter dedicated for Pt100 sensors
- IPAQ R202 is a digital, easy-to-use temperature transmitter developed specifically for measurements with Pt100 sensors.
- Its robust design and high quality gives excellent performance and accuracy also under harsh conditions.
- With the new runtime counter function you can easily supervise the elapsed operational time between calibrations.
- Robust terminals
- Input: Pt100 in 3-wire connection
- PC configurable measuring ranges without need for calibration
- Floating zero with minimum span 20°C
- Temperature linear output
- Runtime counter
- Excellent EMC immunity
- Configuration without external power
- Easy-to-use Windows configuration software
- USB communication
- Withstands vibrations up to 10 g
Technical data:
- Type: Rail mounted
- Input: RTD
- Input RTD: Pt100
- Type of transmitter: Digital
- Output: 4-20 mA
- Isolation: Unisolated
- Measuring channels: 1 channel
- Sensor connection: 3-wire connection
- Power Supply: Standard version: 6 to 32 VDC
- Typical accuracy: Max. ±0.1K or ±0,1 % of span
Dimensions:
Connection diagram:
You can download more at the document here: Download
Related products
2-wire Transmitters
- Type: Rail-mounted
- Input: RTD, Thermocouple, Universal
- Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input Thermocouple: Type B, C, E, J, K, L, N, R, S, T, U
- Output: 4-20 mA
- Isolation: Isolated
- Measuring channels: 1 channel
- Sensor connection: 3-, 4-wire connection
- Approvals: ATEX
- Typical accuracy: ±0.1 % of span
2-wire Transmitters
- Type: Rail-mounted
- Input: RTD, TC, mV, ohm
- Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input thermocouple: Type B, C, D, E, J, K, N, R, S, T
- Output: 4-20 mA, HART protocol
- Galvanic isolation: 1500 VAC
- Measuring channels: 1 channel
- Sensor connection: 2-, 3-, 4-wire connection
2-wire Transmitters
- Type: Head mounted
- Input: RTD
- Input RTD: Pt100
- Type of transmitter: Digital
- Output: 4-20 mA
- Isolation: Unisolated
- Measuring channels: 1 channel
- Sensor connection: 3-wire connection
2-wire Transmitters
- Type: Head mounted
- Input: Pt100, Pt1000
- Type of transmitter: Digital
- Output: 4-20 mA
- Measuring range: –200…+850 °C / -328…+1562 °F
- Typical accuracy: Max. ±0,15 K or ±0,15 % of span
- Configuration: App INOR Connect*
- Wireless communication: NFC®
2-wire Transmitters
- Type: Rail-mounted
- Input: RTD; Thermocouple; Universal
- Input: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input Thermocouple: Type B, C, E, J, K, L, N, R, S, T, U
- Output: 4-20 mA
- Isolation: Isolated
- Measuring channels: 1 channel
- Sensor connection: 3-, 4-wire connection
- Typical accuracy: 0.05% of span