At a glance:
- Rugged, reliable ultrasound technology
- Reliable measurement, regardless of material color, transparency, gloss, or ambient light
- Sensing ranges up to 1,300 mm
- Easy integration due to a short M18 housing, straight or angled
- Measurement filters and variants with temperature compensation for reliable measurement results and very high process reliability
- Synchronization or multiplex mode for the simultaneous use of up to 20 sensors increases application flexibility and process reliability
Technical data:
- Measuring range
Operating range: 20 mm … 1,000 mm
Limiting range: 250 mm … 1,300 mm
- Resolution: 0.069 mm … 0.2 mm
- Repeatability: ± 0.15 %
- Response time: 32 ms … 80 ms/ 32 ms … 80 ms
- Output time: 8 ms … 20 ms
- Switching frequency: ± 15 Hz/ 25 Hz/ 12 Hz/ 10 Hz
- Analog output: 4 mA … 20 mA, ≤ 500 Ω/ 0 V … 10 V, ≥ 100,000 Ω/ 0 V … 10 V, ≥ 100,000 Ω
- Digital output: PNP / NPN / push-pull: PNP/NPN
- IO-Link: ✔ / IO-Link V1.0 / ✔ / IO-Link V1.1
- Enclosure rating: IP65 / IP67
- Sending axis: Straight / angled
Dimensions:
Connection diagram: