At a glance:
- For the control of ventilation and for filter monitoring in road tunnels
- Low maintenance requirements due to long maintenance interval (approx. 1 year)
- Very rugged design in stainless steel
- Automatic beam alignment between sender/receiver unit and reflector
Technical data:
- Measured values: Visibility (K-value), NO, NO2, NOx, CO, temperature
- Measurement principles: Differential optical absorption spectroscopy (DOAS), transmittance measurement, electrochemical cell, Resistance thermometer
- Measuring distance: 10 m
- Measuring ranges
K-value: 0 … 15 km⁻¹ / 0 … 200 km⁻¹
NO: 0 … 20 ppm / 0 … 45 ppm
NO2: 0 … 1 ppm / 0 … 5 ppm
CO: 0 … 100 ppm / 0 … 300 ppm
- Temperature: –25 … +55 °C / –25 … +75 °C
- Response time (t90)
Visibility (K-value): 5 s … 360 s, Adjustable (45 s pre-configured)
NO, NO2: 5 s … 360 s, Adjustable (45 s pre-configured)
CO: ≤ 60 s
- Linearity
NO: ± 0.48 ppm
NO2: ± 0.035 ppm
- Detection limit
Visibility (K-value): 0.03 km⁻¹
NO: 0.002 ppm
NO2: 0.007 ppm
- Repeatability
Visibility (K-value): 0.017 km⁻¹
NO: 0.031 ppm
NO2: 0.007 ppm
- Ambient temperature: –20 °C … +55 °C; CO sensor: –10 °C … +40 °C
- Storage temperature: –25 °C … +75 °C; CO sensor: 0 °C … +20 °C
- Ambient pressure: 700 hPa … 1,200 hPa
- Ambient humidity: 10 % … 95 %; Relative humidity; non-condensing
- Conformities
ASTRA “Guideline – Ventilation of Road Tunnels” (2008)
RABT 2006
RVS 09.02.22
- Electrical safety: CE
- Enclosure rating: IP69K
Dimensions:
VICOTEC320 sender/receiver unit
Reflector unit
VICOTEC320 connection unit
Connection diagram: