- Type: Rail-mounted
- Input: RTD; Thermocouple; Universal
- Input: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input Thermocouple: Type B, C, E, J, K, L, N, R, S, T, U
- Type Of Transmitter: Digital
- Output: 4-20 mA
- Isolation: Isolated
- Measuring channels: 1 channel
- Sensor connection: 3-, 4-wire connection
- Power supply: 7.5 to 36 VDC
- Typical accuracy: 0.05% of span
2-wire transmitter IPAQ-Lplus
- Type: Rail-mounted
- Input: RTD; Thermocouple; Universal
- Input: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input Thermocouple: Type B, C, E, J, K, L, N, R, S, T, U
- Output: 4-20 mA
- Isolation: Isolated
- Measuring channels: 1 channel
- Sensor connection: 3-, 4-wire connection
- Typical accuracy: 0.05% of span
Category: 2-wire Transmitters
Tag: test
At a glance:
- IPAQ-LPLUS offers outstanding accuracy, stability and high isolation combined with short response time and extended functionality.
- It is a universal 2-wire transmitter for high-demand temperature and process measurement applications.
- Error corrections and sensor diagnostics improve the measurement accuracy and safety.
- Fully universal, linearized and highly isolated
- Accepts RTD, T/C, mV and Ω
- Extra high accuracy and stability
- Sensor error and system (sensor/transmitter) error correction for
- highest total accuracy
- 40 point linearization – any sensor can be matched
- Configuration without external power
- High speed update (300 ms)
- Selectable output limits
- Low sensor isolation detection
- Full access to all features while in operatio
- NAMUR compliant
- Simplified loop check-up with calibration output
- Test output without breaking the loop
- IPRO, easy-to-use Windows configuration software
Technical data:
- Type: Rail-mounted
- Input: RTD; Thermocouple; Universal
- Input: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input Thermocouple: Type B, C, E, J, K, L, N, R, S, T, U
- Type Of Transmitter: Digital
- Output: 4-20 mA
- Isolation: Isolated
- Measuring channels: 1 channel
- Sensor connection: 3-, 4-wire connection
- Power supply: 7.5 to 36 VDC
- Typical accuracy: 0.05% of span
Dimensions:
Connection diagram:
You can download more at the document here: Download
Related products
2-wire Transmitters
- Type: Head-mounted
- Input: RTD; Thermocouple; Universal
- Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input Thermocouple: Type B, C, E, J, K, L, N, R, S, T, U
- Output: 4-20 mA
- Isolation: Isolated
- Measuring channels: 1 channel
- Input connection: 3-, 4-wire connection
- Typical accuracy: 0.05% of span
Switching automation light grids
- Operating range: 1.5 m ... 12 m
- Different beam resolutions 10 mm, 30 mm and 60 mm
- High immunity to ambient light when exposed to sunlight and reflective objects, eliminating false trips
- A high operating reserve increases application availability and reduces maintenance costs
- Optical synchronization enables quick installation and cost-effective connection
- The sensitivity adjustment enables trouble-free operation without reflection problems for the customer
2-wire Transmitters
- Type: Head mounted
- Input: Pt100, Pt1000
- Type of transmitter: Digital
- Output: 4-20 mA
- Measuring range: –200…+850 °C / -328…+1562 °F
- Typical accuracy: Max. ±0,15 K or ±0,15 % of span
- Configuration: App INOR Connect*
- Wireless communication: NFC®
2-wire Transmitters
- Type: Rail-mounted
- Input: RTD; Thermocouple; Universal
- Input RTD: Pt10, Pt50, Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input Thermocouple: Type B, C, D, E, J, K, N, R, S, T
- Output: 4-20 mA; HART®
- Isolation: Isolated
- Measuring channels: 2 channels
- Sensor connection: 2-, 3-, 4-wire connection
- Approvals: ATEX, IECEx, SIL2
2-wire Transmitters
- Type: Head-mounted
- Input RTD: Pt100, Pt1000
- Output: 0-10 V
- Isolation: Unisolated
- Measuring channels: 1 channel
- Input connections: 3-wire connection
- Power supply: 15 to 30 VDC