- Type: Rail-mounted
- Input: RTD; Thermocouple; Universal
- Input: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input Thermocouple: Type B, C, E, J, K, L, N, R, S, T, U
- Type Of Transmitter: Digital
- Output: 4-20 mA
- Isolation: Isolated
- Measuring channels: 1 channel
- Sensor connection: 3-, 4-wire connection
- Power supply: 7.5 to 36 VDC
- Typical accuracy: 0.05% of span
2-wire transmitter IPAQ-Lplus
- Type: Rail-mounted
- Input: RTD; Thermocouple; Universal
- Input: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input Thermocouple: Type B, C, E, J, K, L, N, R, S, T, U
- Output: 4-20 mA
- Isolation: Isolated
- Measuring channels: 1 channel
- Sensor connection: 3-, 4-wire connection
- Typical accuracy: 0.05% of span
Category: 2-wire Transmitters
Tag: test
At a glance:
- IPAQ-LPLUS offers outstanding accuracy, stability and high isolation combined with short response time and extended functionality.
- It is a universal 2-wire transmitter for high-demand temperature and process measurement applications.
- Error corrections and sensor diagnostics improve the measurement accuracy and safety.
- Fully universal, linearized and highly isolated
- Accepts RTD, T/C, mV and Ω
- Extra high accuracy and stability
- Sensor error and system (sensor/transmitter) error correction for
- highest total accuracy
- 40 point linearization – any sensor can be matched
- Configuration without external power
- High speed update (300 ms)
- Selectable output limits
- Low sensor isolation detection
- Full access to all features while in operatio
- NAMUR compliant
- Simplified loop check-up with calibration output
- Test output without breaking the loop
- IPRO, easy-to-use Windows configuration software
Technical data:
- Type: Rail-mounted
- Input: RTD; Thermocouple; Universal
- Input: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input Thermocouple: Type B, C, E, J, K, L, N, R, S, T, U
- Type Of Transmitter: Digital
- Output: 4-20 mA
- Isolation: Isolated
- Measuring channels: 1 channel
- Sensor connection: 3-, 4-wire connection
- Power supply: 7.5 to 36 VDC
- Typical accuracy: 0.05% of span
Dimensions:
Connection diagram:
You can download more at the document here: Download
Related products
2-wire Transmitters
- Type: Head-mounted
- Input: RTD, TC, mV, ohm
- Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input thermocouple: Type B, C, D, E, J, K, N, R, S, T
- Output: 4-20 mA
- Galvanic isolation: 1500 VAC
- Measuring channels: 1 channel
- Sensor connection: 2-, 3-, 4-wire connection
- Power supply: IPAQ-C330: 8 to 36 VDC/ IPAQ-C330X: 8 to 30 VDC
2-wire Transmitters
- Type: Rail mounted
- Input RTD: Pt100
- Type of transmitter: Digital
- Output: 4-20 mA
- Isolation: Unisolated
- Measuring channels: 1 channel
- Sensor connection: 3-wire connection
- Power Supply: Standard version: 6 to 32 VDC
- Typical accuracy: Max. ±0.1K or ±0,1 % of span
2-wire Transmitters
- Type: Head-mounted
- Input: RTD; Thermocouple; Universal
- Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input Thermocouple: Type B, C, E, J, K, L, N, R, S, T, U
- Output: 4-20 mA
- Isolation: Isolated
- Measuring channels: 1 channel
- Input connection: 3-, 4-wire connection
- Typical accuracy: 0.05% of span
2-wire Transmitters
- Type: Head mounted
- Input: Pt100, Pt1000
- Type of transmitter: Digital
- Output: 4-20 mA
- Measuring range: –200…+850 °C / -328…+1562 °F
- Typical accuracy: Max. ±0,15 K or ±0,15 % of span
- Configuration: App INOR Connect*
- Wireless communication: NFC®
2-wire Transmitters
- Type: Rail-mounted
- Input: RTD, TC, mV, ohm
- Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input thermocouple: Type B, C, D, E, J, K, N, R, S, T
- Output: 4-20 mA
- Galvanic isolation: 1500 VAC
- Measuring channels: 1 channel
- Sensor connection: 2-, 3-, 4-wire connection