- Type: Head-mounted
- Input: RTD
- Input RTD: Pt100, Pt1000
- Type Of Transmitter: Analog
- Output: 0-10 V
- Isolation: Unisolated
- Measuring channels: 1 channel
- Input connections: 3-wire connection
- Power supply: 15 to 30 VDC
3-wire transmitter APAQ-3HPT
- Type: Head-mounted
- Input RTD: Pt100, Pt1000
- Output: 0-10 V
- Isolation: Unisolated
- Measuring channels: 1 channel
- Input connections: 3-wire connection
- Power supply: 15 to 30 VDC
Category: 2-wire Transmitters
At a glance:
- APAQ-3HPT is a multirange 3-wire temperature transmitter with Pt100 or Pt1000 input and 0-10 V output. Main applications are in the HVAC sector, where the control systems often require 0-10 V input signals.
- APAQ-3HPT is designed for high reliability and good industrial performance.
- The “low profile” housing is extremely durable and facilitates easy connections and adjustments.
- Rangeable with solder pads and potentiometers
- Temperature linear output
- Selectable sensor break function
- Short-circuit protected output
- Polarity protected power supply
- Easy wiring, large center hole
Technical data:
- Type: Head-mounted
- Input: RTD
- Input RTD: Pt100, Pt1000
- Type Of Transmitter: Analog
- Output: 0-10 V
- Isolation: Unisolated
- Measuring channels: 1 channel
- Input connections: 3-wire connection
- Power supply: 15 to 30 VDC
Dimensions:
Connection diagram:
You can download more at the document here: Download
Related products
2-wire Transmitters
- Type: Rail mounted
- Input RTD: Pt100
- Type of transmitter: Digital
- Output: 4-20 mA
- Isolation: Unisolated
- Measuring channels: 1 channel
- Sensor connection: 3-wire connection
- Power Supply: Standard version: 6 to 32 VDC
- Typical accuracy: Max. ±0.1K or ±0,1 % of span
2-wire Transmitters
- Type: Rail-mounted
- Input: RTD; Thermocouple; Universal
- Input: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input Thermocouple: Type B, C, E, J, K, L, N, R, S, T, U
- Output: 4-20 mA
- Isolation: Isolated
- Measuring channels: 1 channel
- Sensor connection: 3-, 4-wire connection
- Typical accuracy: 0.05% of span
2-wire Transmitters
- Type: Rail-mounted
- Input: RTD, TC, mV, ohm
- Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input thermocouple: Type B, C, D, E, J, K, N, R, S, T
- Output: 4-20 mA, HART protocol
- Galvanic isolation: 1500 VAC
- Measuring channels: 1 channel
- Sensor connection: 2-, 3-, 4-wire connection
2-wire Transmitters
- Type: Rail mounted
- Input: Pt100, Pt1000
- Type of transmitter: Digital
- Output: 4-20 mA
- Measuring range: –200…+850 °C / -328…+1562 °F
- Typical accuracy: Max. ±0,15 K or ±0,15 % of span
- Configuration: App INOR Connect*
- Wireless communication: NFC®
2-wire Transmitters
- Type: Head-mounted
- Input: RTD, TC, mV, ohm
- Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input thermocouple: Type B, C, D, E, J, K, N, R, S, T
- Output: 4-20 mA
- Galvanic isolation: 1500 VAC
- Measuring channels: 1 channel
- Sensor connection: 2-, 3-, 4-wire connection
- Power supply: IPAQ-C330: 8 to 36 VDC/ IPAQ-C330X: 8 to 30 VDC