At a glance:
- Wide measurement ranges up to 10, 20 or 50 m in combination with different interfaces allow an easy and fast integration in any production environment
- Temperature range from –30 °C to +65 °C allows for outdoor use without additional cooling or heating
- Up to 40 klx ambient light immunity – allows for use in optically challenging environments
- Highest reliability, ambient light immunity and price/performance ratio thanks to HDDM technology
Technical data:
- Measuring range: 200 mm … 50,000 mm, 90 % remission, 18 % remission, 6 % remission, on reflective tape “Diamond Grade”
- Repeatability: ≥ 2.5 mm/ ≥ 1 mm/ ≥ 2 mm/ ≥ 0.25 mm
- Accuracy: ± 10 mm/ ± 7 mm/ ± 3 mm
- Response time: 20 ms … 30 ms/ 15 ms … 80 ms/ 10 ms … 50 ms/ 20 ms … 100 ms/ 15 ms … 30 ms/ 10 ms … 160 ms
- Serial: ✔ , RS-422
- SSI: ✔
- Analog output: Current output / voltage output
- Digital output: 1 … 2 x PNP/ 1 … 2 x NPN
- Ambient temperature operation: –30 °C … +65 °C/ –30 °C … +80 °C, operation with 2 cooling plates/ –30 °C … +140 °C, operation with 2 cooling plates and protection filter
- Light source: Laser, red
- Laser class: 2 (IEC 60825-1:2014)/ 1 (IEC 60825-1:2014)
Dimensions:
Connection diagram: