- Type: Rail-mounted
- Input: RTD; Thermocouple; Universal
- Input: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input Thermocouple: Type B, C, E, J, K, L, N, R, S, T, U
- Type Of Transmitter: Digital
- Output: 4-20 mA
- Isolation: Isolated
- Measuring channels: 1 channel
- Sensor connection: 3-, 4-wire connection
- Power supply: 7.5 to 36 VDC
- Typical accuracy: 0.05% of span
2-wire transmitter IPAQ-Lplus
- Type: Rail-mounted
- Input: RTD; Thermocouple; Universal
- Input: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input Thermocouple: Type B, C, E, J, K, L, N, R, S, T, U
- Output: 4-20 mA
- Isolation: Isolated
- Measuring channels: 1 channel
- Sensor connection: 3-, 4-wire connection
- Typical accuracy: 0.05% of span
Category: 2-wire Transmitters
Tag: test
At a glance:
- IPAQ-LPLUS offers outstanding accuracy, stability and high isolation combined with short response time and extended functionality.
- It is a universal 2-wire transmitter for high-demand temperature and process measurement applications.
- Error corrections and sensor diagnostics improve the measurement accuracy and safety.
- Fully universal, linearized and highly isolated
- Accepts RTD, T/C, mV and Ω
- Extra high accuracy and stability
- Sensor error and system (sensor/transmitter) error correction for
- highest total accuracy
- 40 point linearization – any sensor can be matched
- Configuration without external power
- High speed update (300 ms)
- Selectable output limits
- Low sensor isolation detection
- Full access to all features while in operatio
- NAMUR compliant
- Simplified loop check-up with calibration output
- Test output without breaking the loop
- IPRO, easy-to-use Windows configuration software
Technical data:
- Type: Rail-mounted
- Input: RTD; Thermocouple; Universal
- Input: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input Thermocouple: Type B, C, E, J, K, L, N, R, S, T, U
- Type Of Transmitter: Digital
- Output: 4-20 mA
- Isolation: Isolated
- Measuring channels: 1 channel
- Sensor connection: 3-, 4-wire connection
- Power supply: 7.5 to 36 VDC
- Typical accuracy: 0.05% of span
Dimensions:
Connection diagram:
You can download more at the document here: Download
Related products
2-wire Transmitters
- Type: Head mounted
- Input: RTD
- Input RTD: Pt100
- Type of transmitter: Digital
- Output: 4-20 mA
- Isolation: Unisolated
- Measuring channels: 1 channel
- Sensor connection: 3-wire connection
2-wire Transmitters
- Type: Rail-mounted
- Input: RTD, TC, mV, ohm
- Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
- Input thermocouple: Type B, C, D, E, J, K, N, R, S, T
- Output: 4-20 mA
- Galvanic isolation: 1500 VAC
- Measuring channels: 1 channel
- Sensor connection: 2-, 3-, 4-wire connection
Signal isolation
- The Signal Splitter/Repeater IspPAQ-632 is used for isolation, conversion and distribution of 0/4 … 20 mA, 0/1 … 5 V and 0/2 … 10 V standard signals. The measuring input can also supply the loop power for 2-wire transmitters.
- Input signal (calibrated switchable): 0 … 20 mA, 0 … 10 V, 0 … 5 V/ 4 … 20 mA, 2 … 10 V, 1 … 5 V
- Output signal (calibrated switchable): 0 … 20 mA, 0 … 10 V, 0 … 5 V/ 4 … 20 mA, 2 … 10 V, 1 … 5 V
- The input and two isolated outputs can be easily configured by using DIP switch. Due to the calibrated range selection no further adjustment is necessary
Transmittance dust Measuring Devices
- The DUSTHUNTER T200 is a measuring device for dust at medium to high concentrations
- For medium to high dust concentrations
- Emissions monitoring at power plants and waste incineration plants
- Monitoring of filter systems
- Monitoring of dust load in factory halls
- Control of fresh air and exhaust air units
Transmittance dust Measuring Devices
- The DUSTHUNTER C200 is a type-approved measuring device which combines the advantages of the measuring principles of transmittance and forward scattered light
- Combination of transmittance and scattered light measurement
- For very low to high dust concentrations
- For medium to large duct diameters
- Emissions monitoring at power plants and waste incineration plants
- Monitoring of filter systems
- Measurement of dust concentration in exhaust gas and exhaust air ducts upstream and downstream of filters