- Input mA: -1 to +50 mA
- Input impedance: 10 Ω
- Adjustments – Zero: Any value within range limits
- Adjustments – Minimum spans: 0,4 mA
- Output: 4-20 / 20-4 mA
- Operating temperature: -20 to +70 °C / -4 to +158 °F
- Galvanic isolation: 1500 VAC, 1 min
- Power supply: 7,5 to 36 VDC
- Typical accuracy: ±0,1 % of span
- Mounting: DIN-rail acc. DIN EN50022, 35 mm
Isolators IPAQ-L(MA)
- Input mA: -1 to +50 mA
- Input impedance: 10 Ω
- Adjustments – Zero: Any value within range limits
- Adjustments – Minimum spans: 0,4 mA
- Output: 4-20 / 20-4 mA
- Galvanic isolation: 1500 VAC, 1 min
- Power supply: 7,5 to 36 VDC
- Typical accuracy: ±0,1 % of span
Category: Signal isolation
Tag: test
At a glance:
- IPAQ-L(mA) is an active isolation transmitter for mA input signals with a 4-20 mA output in a 2-wire connection. It is suitable for direct connection to the input modules of a control system.
- Thanks to the programmable input range and the low input impedance, IPAQ-L(mA) meets almost any need for current signal isolation and load amplification.
- Input: mA signal
- Programmable measuring range within -1 to +50 mA
- Output: 4-20 mA in 2-wire connection
- 1500 VAC isolation input/output
- Low input impedance
- Full access to all features while in operation
- Simplified loop check-up with calibration output
- Test output without breaking the loop
- IPRO, easy-to-use Windows configuration software
Technical data:
- Input mA: -1 to +50 mA
- Input impedance: 10 Ω
- Adjustments – Zero: Any value within range limits
- Adjustments – Minimum spans: 0,4 mA
- Output: 4-20 / 20-4 mA
- Operating temperature: -20 to +70 °C / -4 to +158 °F
- Galvanic isolation: 1500 VAC, 1 min
- Power supply: 7,5 to 36 VDC
- Typical accuracy: ±0,1 % of span
- Mounting: DIN-rail acc. DIN EN50022, 35 mm
Dimensions:
Connection diagram:
You can download more at the document here: Download
Related products
Hot-wet Extractive gas analyzers
- CEMS solutions MCS200HW
- The MCS200HW is a multi-component analyzer system for continuous monitoring of up to 10 IR measurement components in flue gases of industrial combustion plants
- Measured values: CH4, CO, CO2, Corg, HCl, H2O, H2SO4, NH3, NO, NO2, N2O, O2, SO2, SO3
- Emission monitoring for waste incineration plants as well as power plants and plants with co-incineration, e.g. cement plants
- Measurement of nitrogen oxides (NO, NO2, N2O) in nitric acid plants
- SO3 monitoring in coal-fired power plants
Scattered light dust Measuring Devices
- The DUSTHUNTER SB50 is a measuring device for dust at low to medium concentrations in challenging applications, e. g., in hot or corrosive gases
- For low to medium dust concentrations
- Emission monitoring of heating installations
- Monitoring of dust concentrations downstream of filter plants
- Dust concentration measurement in cement plants
General Service Valves
- Valve Actuation: Solenoid
- Body Material: Aluminum
- Media: Air, Inert Gas, Liquid Propane Gas, Natural Gas, Oxygen
- The ASCO Series 214 gas shutoff valves are specifically designed for on-off control of fuel gas in commercial and industrial gas burners.
- Broad ambient range of -40°F to 140°F is ideally suited for frigid and hot environments
2-wire Transmitters
- Type: Head mounted
- Input: RTD
- Input RTD: Pt100
- Type of transmitter: Digital
- Output: 4-20 mA
- Isolation: Unisolated
- Measuring channels: 1 channel
- Sensor connection: 3-wire connection
Fuel, Gas & Oil Valves
- Valve Actuation: Solenoid
- Body Material: Aluminum
- Media: Natural Gas
- The ASCO Series S261 is a line of solenoid valves designed for on-off control of fuel gas in commercial and industrial gas burners.
- Suitable for ambient temperatures up to 175°F