2-wire Transmitters

2-wire transmitter IPAQ R202

  • Type: Rail mounted
  • Input RTD: Pt100
  • Type of transmitter: Digital
  • Output: 4-20 mA
  • Isolation: Unisolated
  • Measuring channels: 1 channel
  • Sensor connection: 3-wire connection
  • Power Supply: Standard version: 6 to 32 VDC
  • Typical accuracy: Max. ±0.1K or ±0,1 % of span

2-wire Transmitters

2-wire transmitter IPAQ-21

  • Type: Rail-mounted
  • Input: RTD, Thermocouple, Universal
  • Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
  • Input Thermocouple: Type B, C, E, J, K, L, N, R, S, T, U
  • Output: 4-20 mA
  • Isolation: Isolated
  • Measuring channels: 1 channel
  • Sensor connection: 3-, 4-wire connection
  • Approvals: ATEX
  • Typical accuracy: ±0.1 % of span

2-wire Transmitters

2-wire transmitter IPAQ R520

  • Type: Rail-mounted
  • Input: RTD; Thermocouple; Universal
  • Input RTD: Pt10, Pt50, Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni1000, Cu10
  • Input Thermocouple: Type B, C, D, E, J, K, N, R, S, T
  • Output: 4-20 mA; HART®
  • Isolation: Isolated
  • Measuring channels: 2 channels
  • Sensor connection: 2-, 3-, 4-wire connection
  • Approvals: ATEX, IECEx, SIL2

2-wire Transmitters

2-wire transmitter MinIPAQ-L

  • Type: Rail-mounted
  • Input: RTD; Thermocouple
  • Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
  • Input Thermocouple: Type B, C, E, J, K, L, N, R, S, T, U
  • Output: 4-20 mA
  • Isolation: Unisolated
  • Measuring channels: 1 channel
  • Sensor connection: 3-, 4-wire connection
  • Typical accuracy: 0.15% of span

2-wire Transmitters

2-wire transmitter IPAQ-Lplus

  • Type: Rail-mounted
  • Input: RTD; Thermocouple; Universal
  • Input: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
  • Input Thermocouple: Type B, C, E, J, K, L, N, R, S, T, U
  • Output: 4-20 mA
  • Isolation: Isolated
  • Measuring channels: 1 channel
  • Sensor connection: 3-, 4-wire connection
  • Typical accuracy: 0.05% of span

2-wire Transmitters

2-wire transmitter IPAQ-Hplus

  • Type: Head-mounted
  • Input: RTD; Thermocouple; Universal
  • Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
  • Input Thermocouple: Type B, C, E, J, K, L, N, R, S, T, U
  • Output: 4-20 mA
  • Isolation: Isolated
  • Measuring channels: 1 channel
  • Input connection: 3-, 4-wire connection
  • Typical accuracy: 0.05% of span

2-wire Transmitters

3-wire transmitter APAQ-3HPT

  • Type: Head-mounted
  • Input RTD: Pt100, Pt1000
  • Output: 0-10 V
  • Isolation: Unisolated
  • Measuring channels: 1 channel
  • Input connections: 3-wire connection
  • Power supply: 15 to 30 VDC

3-wire Transmitters

3-wire transmitter APAQ-3LPT

  • Type: Rail-mounted
  • Input RTD: Pt100, Pt1000
  • Output: 0-10 V
  • Isolation : Unisolated
  • Measuring channels: 1 channel
  • Sensor connection: 3-wire connection
  • Power supply: 15 to 30 VDC
  • Typical accuracy: 0.15% of span

4-wire Transmitters

4-wire transmitter IPAQ-4L

  • Type: Rail-mounted
  • Input: RTD; Thermocouple; Universal
  • Input RTD: Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10
  • Input Thermocouple: Type B, C, E, J, K, L, N, R, S, T, U
  • Output: 4-20 mA; 0-10 V
  • Isolation : Isolated
  • Measuring channels: 1 channel
  • Sensor connection: 3-, 4-wire connection
  • Typical accuracy: 0.1% of span

Indicators

Indicators LED-W11

  • Type of Display: LED
  • Input Current: 4-20 mA
  • Indication range: -1999 to 9999
  • Digit height: 14,2 mm
  • Protection class: IP65 / NEMA 4X
  • Typical accuracy: 0,05 % FS ±1 digit
  • Dimensions: 80 x 110 x 65 mm

Indicators

Indicators LCD-W11

  • Type of Display: LCD
  • Input Current: 4-20 mA
  • Indication range: -1999 to 9999
  • Digit height: 17,8 mm
  • Protection class: IP65 / NEMA 4X
  • Typical accuracy: 0,05 % FS ±1 digit
  • Dimensions: 80 x 110 x 65 mm

  • Type of Display: LED
  • Input Current: 4-20 mA
  • Approvals: ATEX
  • Indication range: -1999 to 9999
  • Digit height: 14,2 mm
  • Protection class: IP65 / NEMA 4X
  • Typical accuracy: 0,05 % FS ±1 digit
  • Dimensions: 125 x 80 x 63 mm